Analysis of the temperature evolution of the canned motor with spiral tube heat exchanger in secondary water supply blackout fault

In a canned motor with a spiral tube heat exchanger for a nuclear main pump, if the secondary water suddenly fails, the temperature of the lubricating water and motor winding insulation must not exceed the alarm or permitted value within the 5 min response time for safe operation. Therefore, it is crucial to predict the transient characteristics of the temperature distribution of the cooling water and the main components. In this paper, a finite-volume conjugate 3D thermal model is proposed to predict the steady-state/unsteady temperature fields of the small-capacity canned motor for a nuclear main pump. The temperature development characteristics of the main components and the primary/secondary water are analyzed under rated conditions with cold ambient parameters. The predicted temperatures agree well with the measured experimental data a maximum error of + 5.97%. Results show that the temperature difference between the stator/rotor cores and the shielding sleeves becomes smaller than in the steady state. The temperature of the coolant in the nuclear main pump under the motor bottom has an increasing influence on the motor bottom lubricating water temperature over time during transient SWSB failure conditions. It provides references for the thermal design of canned motors for nuclear main pumps.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-07
DOI
https://doi.org/10.1038/s41598-025-18704-5
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the temperature evolution of the canned motor with spiral tube heat exchanger in secondary water supply blackout fault

Likun Ai, Yiping Lu
Scientific Reports
Superconducting Materials and Applications
article

Analysis of the temperature evolution of the canned motor with spiral tube heat exchanger in secondary water supply blackout fault

Likun Ai, Yiping Lu
article en

Abstract

In a canned motor with a spiral tube heat exchanger for a nuclear main pump, if the secondary water suddenly fails, the temperature of the lubricating water and motor winding insulation must not exceed the alarm or permitted value within the 5 min response time for safe operation. Therefore, it is crucial to predict the transient characteristics of the temperature distribution of the cooling water and the main components. In this paper, a finite-volume conjugate 3D thermal model is proposed to predict the steady-state/unsteady temperature fields of the small-capacity canned motor for a nuclear main pump. The temperature development characteristics of the main components and the primary/secondary water are analyzed under rated conditions with cold ambient parameters. The predicted temperatures agree well with the measured experimental data a maximum error of + 5.97%. Results show that the temperature difference between the stator/rotor cores and the shielding sleeves becomes smaller than in the steady state. The temperature of the coolant in the nuclear main pump under the motor bottom has an increasing influence on the motor bottom lubricating water temperature over time during transient SWSB failure conditions. It provides references for the thermal design of canned motors for nuclear main pumps.

Scientific ReportsVol. 15(1)
Qiqihar University (CN), Luye Pharma (China) (CN), Shandong University of Science and Technology (CN)
Openalex Percentile: Top 73%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies