Hierarchical Deep Learning for Abnormality Classification in Mouse Skeleton Using Multiview X-Ray Images: Convolutional Autoencoders Versus ConvNeXt

Single-view-based anomaly detection approaches present challenges due to the lack of context, particularly for multi-label problems. In this work, we demonstrate the efficacy of using multiview image data for improved classification using a hierarchical learning approach. Using 170,958 images from the International Mouse Phenotyping Consortium (IMPC) repository, a specimen-wise multiview dataset comprising 54,046 specimens was curated. Next, two hierarchical classification frameworks were developed by customizing ConvNeXT and a convolutional autoencoder (CAE) as CNN backbones, respectively. The customized architectures were trained at three hierarchy levels with increasing anatomical granularity, enabling specialized layers to learn progressively more detailed features. At the top level (L1), multiview (MV) classification performed about the same as single views, with a high mean AUC of 0.95. However, using MV images in the hierarchical model greatly improved classification at levels 2 and 3. The model showed consistently higher average AUC scores with MV compared to single views such as dorsoventral or lateral. For example, at Level 2 (L2), the model divided abnormal cases into three subclasses, achieving AUCs of 0.65 for DV, 0.76 for LV, and 0.87 for MV. Then, at Level 3 (L3), it further divided these into ten specific abnormalities, with AUCs of 0.54 for DV, 0.59 for LV, and 0.82 for MV. A similar performance was achieved by the CAE-driven architecture, with mean AUCs of 0.87, 0.88, and 0.89 at Level 2 (L2) and 0.74, 0.78, and 0.81 at Level 3 (L3), respectively, for DV, LV, and MV views. The overall results demonstrate the advantage of multiview image data coupled with hierarchical learning for skeletal abnormality detection in a multi-label context.

Authors

Institutions

Publication Details

Journal
Journal of Imaging
Published
2025-10-07
DOI
https://doi.org/10.3390/jimaging11100348
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hierarchical Deep Learning for Abnormality Classification in Mouse Skeleton Using Multiview X-Ray Images: Convolutional Autoencoders Versus ConvNeXt

James M. Brown, Rasneer Sonia Bains, Sara Wells, Muhammad Moazzam Jawaid
Journal of Imaging
Cell Image Analysis Techniques
article

Hierarchical Deep Learning for Abnormality Classification in Mouse Skeleton Using Multiview X-Ray Images: Convolutional Autoencoders Versus ConvNeXt

James M. Brown, Rasneer Sonia Bains, Sara Wells, Muhammad Moazzam Jawaid
article en

Abstract

Single-view-based anomaly detection approaches present challenges due to the lack of context, particularly for multi-label problems. In this work, we demonstrate the efficacy of using multiview image data for improved classification using a hierarchical learning approach. Using 170,958 images from the International Mouse Phenotyping Consortium (IMPC) repository, a specimen-wise multiview dataset comprising 54,046 specimens was curated. Next, two hierarchical classification frameworks were developed by customizing ConvNeXT and a convolutional autoencoder (CAE) as CNN backbones, respectively. The customized architectures were trained at three hierarchy levels with increasing anatomical granularity, enabling specialized layers to learn progressively more detailed features. At the top level (L1), multiview (MV) classification performed about the same as single views, with a high mean AUC of 0.95. However, using MV images in the hierarchical model greatly improved classification at levels 2 and 3. The model showed consistently higher average AUC scores with MV compared to single views such as dorsoventral or lateral. For example, at Level 2 (L2), the model divided abnormal cases into three subclasses, achieving AUCs of 0.65 for DV, 0.76 for LV, and 0.87 for MV. Then, at Level 3 (L3), it further divided these into ten specific abnormalities, with AUCs of 0.54 for DV, 0.59 for LV, and 0.82 for MV. A similar performance was achieved by the CAE-driven architecture, with mean AUCs of 0.87, 0.88, and 0.89 at Level 2 (L2) and 0.74, 0.78, and 0.81 at Level 3 (L3), respectively, for DV, LV, and MV views. The overall results demonstrate the advantage of multiview image data coupled with hierarchical learning for skeletal abnormality detection in a multi-label context.

Journal of ImagingVol. 11(10)
Mary Lyon Centre at MRC Harwell (GB), University of Lincoln (GB)
Openalex Percentile: Top 80%
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.