A Fully Integrated Wearable Microfluidic Electrochemical Sensor with Ultrasonic Connecting and Hot-Pressing Bonded Multilayer Structure for Sweat Biomarker Analysis

Wearable microfluidic sweat sensors serve as critical devices for the continuous monitoring of human biomarkers. This research has developed a fully integrated wearable microfluidic electrochemical sensor (FIWMES) for noninvasive, continuous monitoring of glucose, Na<sup>+</sup>, K<sup>+</sup>, and Ca<sup>2+</sup> in human sweat. To address challenges including sample leakage, structure damage, and difficulties of multiple-biomarker detection, a hybrid bonding process that combines ultrasonic connecting and hot-pressing procedures is presented for structural integration of the FIWMES. The bonding process ensures high interfacial bonding strength (>65 N), excellent sealing performance (no leakage after 200 bends), and precise temperature control (<51 °C) inside the microfluidic chamber. By integrating the dendritic sweat-collecting module, microfluidic chamber, and 3D-arranged sensing units, the FIWMES can achieve efficient sweat capture, sample manipulation, and simultaneous biomarker detection. The glucose sensor exhibits a sensitivity of 6.4 μA/mM with strong anti-interference capability, while the Na<sup>+</sup>, K<sup>+</sup>, and Ca<sup>2+</sup> sensors display near-Nernstian responses with sensitivities of 65.3, 64.3, and 38.2 mV/decade, respectively. On-body trials confirm the practical wearability and its ability to accurately track dynamic metabolic changes, such as postprandial increases in sweat glucose and electrolyte variation under water deficiency. With its stability and monitoring capabilities, FIWMES offers a technical platform for the effective management of chronic diseases.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-07
DOI
https://doi.org/10.1021/acs.analchem.5c04641
Citations
26
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
17.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fully Integrated Wearable Microfluidic Electrochemical Sensor with Ultrasonic Connecting and Hot-Pressing Bonded Multilayer Structure for Sweat Biomarker Analysis

Chaojiang Li, Xin Jin, Pingna Zhang, Tianlong Li et al.
26 citations
Analytical Chemistry
Advanced Sensor and Energy Harvesting Materials
17.53
article

A Fully Integrated Wearable Microfluidic Electrochemical Sensor with Ultrasonic Connecting and Hot-Pressing Bonded Multilayer Structure for Sweat Biomarker Analysis

Chaojiang Li, Xin Jin, Pingna Zhang, Tianlong Li, Xianyang Guan, Guodong Liu, Jieliang Zhao, Qifeng Tan, Huiqing Xu
article en
26 citations

Abstract

Wearable microfluidic sweat sensors serve as critical devices for the continuous monitoring of human biomarkers. This research has developed a fully integrated wearable microfluidic electrochemical sensor (FIWMES) for noninvasive, continuous monitoring of glucose, Na<sup>+</sup>, K<sup>+</sup>, and Ca<sup>2+</sup> in human sweat. To address challenges including sample leakage, structure damage, and difficulties of multiple-biomarker detection, a hybrid bonding process that combines ultrasonic connecting and hot-pressing procedures is presented for structural integration of the FIWMES. The bonding process ensures high interfacial bonding strength (>65 N), excellent sealing performance (no leakage after 200 bends), and precise temperature control (<51 °C) inside the microfluidic chamber. By integrating the dendritic sweat-collecting module, microfluidic chamber, and 3D-arranged sensing units, the FIWMES can achieve efficient sweat capture, sample manipulation, and simultaneous biomarker detection. The glucose sensor exhibits a sensitivity of 6.4 μA/mM with strong anti-interference capability, while the Na<sup>+</sup>, K<sup>+</sup>, and Ca<sup>2+</sup> sensors display near-Nernstian responses with sensitivities of 65.3, 64.3, and 38.2 mV/decade, respectively. On-body trials confirm the practical wearability and its ability to accurately track dynamic metabolic changes, such as postprandial increases in sweat glucose and electrolyte variation under water deficiency. With its stability and monitoring capabilities, FIWMES offers a technical platform for the effective management of chronic diseases.

Analytical ChemistryVol. 97(41)
Beijing Institute of Technology (CN), Capital Medical University (CN), Jiangsu University of Technology (CN), Beijing Hospital of Traditional Chinese Medicine (CN)
Openalex Percentile: Top 0%
Advanced Sensor and Energy Harvesting Materials
17.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.