Quantification of head leakage radiation in CyberKnife robotic radiosurgery systems using a multimodal approach

This study aims to measure the head leakage radiation of a CyberKnife system (Model-S7 (without MLC)) in-patient and out-of-patient planes using optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers, and a pressurized ionization chamber-based survey meter, and to compare the measured leakage levels with the limits specified by the International Electrotechnical Commission (IEC) standards. In this study, a CyberKnife LINAC equipped with a 6 MV flattening filter-free (FFF) beam and a maximum circular field size of 6 cm in diameter was utilized. Leakage radiation was assessed for both IRIS and FIXED collimators in their fully closed positions. Three independent measurement techniques were employed to quantify leakage: optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers (ICs), and a pressurized ionization chamber-based survey meter (SM). Leakage measurement points were taken as per the IEC 60601-2-1 report both for in-patient plane and out-of-patient plane. The total number of monitor units (MU) delivered were 500 MU's. The measured average in-patient plane leakage was 0.015% using IC, 0.100% using OSLD and 0.010% using SM, that is well within the tolerance limit of 0.1% according to IEC guidelines. The average leakage for out of patient plane was 0.037%, which is well within the limit of 0.5% as per IEC guidelines. The study measured head leakage radiation of the CyberKnife System using OSLD, ionization chambers, and a survey meter. Leakage levels for both in-patient and out-of-patient planes were significantly below the IEC 60601-2-1 standard limits. This confirms the system's compliance with safety guidelines, ensuring minimal radiation exposure.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-07
DOI
https://doi.org/10.1038/s41598-025-18689-1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of head leakage radiation in CyberKnife robotic radiosurgery systems using a multimodal approach

Munish Gairola, Shashwati Sen, Sandeep Kumar Singh, Abhay Kumar Singh et al.
Scientific Reports
Advanced Radiotherapy Techniques
article

Quantification of head leakage radiation in CyberKnife robotic radiosurgery systems using a multimodal approach

Munish Gairola, Shashwati Sen, Sandeep Kumar Singh, Abhay Kumar Singh, Manindra Bhushan, Debasish Sahoo, Mahipal Mahipal, Pawan Kumar Singh, Dipesh
article en

Abstract

This study aims to measure the head leakage radiation of a CyberKnife system (Model-S7 (without MLC)) in-patient and out-of-patient planes using optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers, and a pressurized ionization chamber-based survey meter, and to compare the measured leakage levels with the limits specified by the International Electrotechnical Commission (IEC) standards. In this study, a CyberKnife LINAC equipped with a 6 MV flattening filter-free (FFF) beam and a maximum circular field size of 6 cm in diameter was utilized. Leakage radiation was assessed for both IRIS and FIXED collimators in their fully closed positions. Three independent measurement techniques were employed to quantify leakage: optically stimulated luminescence dosimeters (OSLDs), vented ionization chambers (ICs), and a pressurized ionization chamber-based survey meter (SM). Leakage measurement points were taken as per the IEC 60601-2-1 report both for in-patient plane and out-of-patient plane. The total number of monitor units (MU) delivered were 500 MU's. The measured average in-patient plane leakage was 0.015% using IC, 0.100% using OSLD and 0.010% using SM, that is well within the tolerance limit of 0.1% according to IEC guidelines. The average leakage for out of patient plane was 0.037%, which is well within the limit of 0.5% as per IEC guidelines. The study measured head leakage radiation of the CyberKnife System using OSLD, ionization chambers, and a survey meter. Leakage levels for both in-patient and out-of-patient planes were significantly below the IEC 60601-2-1 standard limits. This confirms the system's compliance with safety guidelines, ensuring minimal radiation exposure.

Scientific ReportsVol. 15(1)
Safdarjang Hospital (IN), Rajiv Gandhi Cancer Institute and Research Centre (IN), Cancer Hospital and Research Institute (IN), GLA University (IN)
Openalex Percentile: Top 62%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.