Cantilever Type Retaining Wall Design

Retaining walls are a crucial soil control technique for mitigating landslides. The slope conditions at the Karawang site are considered unstable. The purpose of this study is to analyze the design of retaining walls at this location using cantilever retaining walls and manual calculations. Data collection techniques include literature review. The analysis results show that the dimensions of the cantilever retaining wall with dimensions of the total height of the DPT = 3.50 m, the total width of the DPT foundation = 3.80 m, the wall thickness = 0.40-0.60 m, the diameter of the main reinforcement used, D = 19 mm, the diameter of the shrinkage reinforcement used, D = 13 mm, the thickness of the concrete cover, s = 40 mm. Based on the soil profile at the location, the soil behind the DPT wall of the original soil does not meet the safety factor, Volume weight (γ1) = 16.7 kN / m3, Internal friction angle, (φ1) = 15.21 º, Cohesion (c1) = 5.7 kN / m2, so it is necessary to replace the granular soil at the back of the DPT to Volume weight (γ1) = 18.5 kN / m3, Internal friction angle (φ1) = 33 º, Cohesion (c1) = 4.16 kN/m2,

Authors

Publication Details

Journal
Jurnal Ilmiah Teknik
Published
2025-09-25
DOI
https://doi.org/10.56127/juit.v4i3.2286
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cantilever Type Retaining Wall Design

Era Agita Kabdiyono, Imron Rusadi
Jurnal Ilmiah Teknik
Geotechnical and construction materials studies
article

Cantilever Type Retaining Wall Design

Era Agita Kabdiyono, Imron Rusadi
article en

Abstract

Retaining walls are a crucial soil control technique for mitigating landslides. The slope conditions at the Karawang site are considered unstable. The purpose of this study is to analyze the design of retaining walls at this location using cantilever retaining walls and manual calculations. Data collection techniques include literature review. The analysis results show that the dimensions of the cantilever retaining wall with dimensions of the total height of the DPT = 3.50 m, the total width of the DPT foundation = 3.80 m, the wall thickness = 0.40-0.60 m, the diameter of the main reinforcement used, D = 19 mm, the diameter of the shrinkage reinforcement used, D = 13 mm, the thickness of the concrete cover, s = 40 mm. Based on the soil profile at the location, the soil behind the DPT wall of the original soil does not meet the safety factor, Volume weight (γ1) = 16.7 kN / m3, Internal friction angle, (φ1) = 15.21 º, Cohesion (c1) = 5.7 kN / m2, so it is necessary to replace the granular soil at the back of the DPT to Volume weight (γ1) = 18.5 kN / m3, Internal friction angle (φ1) = 33 º, Cohesion (c1) = 4.16 kN/m2,

Jurnal Ilmiah TeknikVol. 4(3)
Openalex Percentile: Top 71%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.