An in vitro study on dentin abrasion comparing two sonic toothbrushes with and without a coating versus an ADA reference manual toothbrush

This in vitro study evaluated dentin abrasion and surface roughness caused by two sonic toothbrushes with different filament coatings compared with those caused by a standard ADA reference manual toothbrush. Standardized dentin samples (n = 8 per group) were prepared from bovine incisors, embedded in acrylic blocks, polished, and hardness-verified using the Vickers method. A central brushing area was created by masking two reference zones with adhesive tape. Brushing simulations were performed in a laboratory device for 10,000 cycles at a load of 1.5 N using a toothpaste slurry (RDA 129) that was prepared at a 1:1.6 water-to-paste ratio. The tested toothbrushes included the ADA reference manual toothbrush (uncoated nylon filaments), the Curaprox Hydrosonic Pro toothbrush (uncoated PBT filaments), and the Curaprox Hydrosonic Black is White toothbrush (charcoal-coated PBT filaments). Dentin loss was measured by noncontact optical profilometry, and surface roughness was assessed by determining the Ra, Rq and Sa values. Data normality was verified using the Shapiro-Wilk test, and differences among groups were analyzed by one-way ANOVA with Bonferroni correction (α = 0.05). Compared with the ADA reference manual toothbrush, both the sonic toothbrushes caused significantly greater dentin loss (p < 0.001), with no significant difference between the sonic models (p > 0.05). The changes in roughness followed a similar pattern. These findings suggest that, under standardized laboratory conditions, sonic toothbrushes, regardless of the use of a filament coating, cause more dentin wear than a manual reference brush. Moreover, greater dentin abrasion was associated with less roughness, indicating an inverse relationship between tissue loss and surface roughness.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-07
DOI
https://doi.org/10.1371/journal.pone.0333705
Primary Topic
Dental Erosion and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An in vitro study on dentin abrasion comparing two sonic toothbrushes with and without a coating versus an ADA reference manual toothbrush

Stefan Zimmer, Mozhgan Bizhang, L Walter, Amir Aminy
PLoS ONE
Dental Erosion and Treatment
article

An in vitro study on dentin abrasion comparing two sonic toothbrushes with and without a coating versus an ADA reference manual toothbrush

Stefan Zimmer, Mozhgan Bizhang, L Walter, Amir Aminy
article en

Abstract

This in vitro study evaluated dentin abrasion and surface roughness caused by two sonic toothbrushes with different filament coatings compared with those caused by a standard ADA reference manual toothbrush. Standardized dentin samples (n = 8 per group) were prepared from bovine incisors, embedded in acrylic blocks, polished, and hardness-verified using the Vickers method. A central brushing area was created by masking two reference zones with adhesive tape. Brushing simulations were performed in a laboratory device for 10,000 cycles at a load of 1.5 N using a toothpaste slurry (RDA 129) that was prepared at a 1:1.6 water-to-paste ratio. The tested toothbrushes included the ADA reference manual toothbrush (uncoated nylon filaments), the Curaprox Hydrosonic Pro toothbrush (uncoated PBT filaments), and the Curaprox Hydrosonic Black is White toothbrush (charcoal-coated PBT filaments). Dentin loss was measured by noncontact optical profilometry, and surface roughness was assessed by determining the Ra, Rq and Sa values. Data normality was verified using the Shapiro-Wilk test, and differences among groups were analyzed by one-way ANOVA with Bonferroni correction (α = 0.05). Compared with the ADA reference manual toothbrush, both the sonic toothbrushes caused significantly greater dentin loss (p < 0.001), with no significant difference between the sonic models (p > 0.05). The changes in roughness followed a similar pattern. These findings suggest that, under standardized laboratory conditions, sonic toothbrushes, regardless of the use of a filament coating, cause more dentin wear than a manual reference brush. Moreover, greater dentin abrasion was associated with less roughness, indicating an inverse relationship between tissue loss and surface roughness.

PLoS ONEVol. 20(10)
Witten/Herdecke University (DE)
Openalex Percentile: Top 71%
Dental Erosion and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An in vitro study on dentin abrasion comparing two sonic toothbrushes with and without a coating versus an ADA reference manual toothbrush — Stefan Zimmer, Mozhgan Bizhang, et al. · PLoS ONE (2025) | TGRS Research Map | TGRS