A Totem Pole PFC Control Based on Dynamic Root Locus with Wide Output Voltage Range and Low THD

The single-stage totem pole power factor correction (PFC) circuit is widely adopted as the front-end topology for on-board chargers (OBC) due to its high power factor (PF) and simplified structure. However, traditional control methods are inadequate for PFC control under a wide range of operating conditions. To address this challenge, this paper establishes a small signal model of the totem pole PFC current inner-loop and introduces a PI control method based on dynamic root locus (DRL-PI). Experimental results on a 3 kW platform show that compared with traditional fixed parameter control, the proposed control method reduces the estimated total harmonic distortion (THD) by 0.74% in constant resistance experiment and 3.36% in constant voltage experiment.

Authors

Institutions

Publication Details

Published
2025-08-15
DOI
https://doi.org/10.1109/wipda-asia63772.2025.11184023
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Totem Pole PFC Control Based on Dynamic Root Locus with Wide Output Voltage Range and Low THD

Xin Xiao, Yong Cheol Kang, Jiajia Guan, Hao Chu et al.
Advanced DC-DC Converters
article

A Totem Pole PFC Control Based on Dynamic Root Locus with Wide Output Voltage Range and Low THD

Xin Xiao, Yong Cheol Kang, Jiajia Guan, Hao Chu, Cai Chen, X. Sun
article en

Abstract

The single-stage totem pole power factor correction (PFC) circuit is widely adopted as the front-end topology for on-board chargers (OBC) due to its high power factor (PF) and simplified structure. However, traditional control methods are inadequate for PFC control under a wide range of operating conditions. To address this challenge, this paper establishes a small signal model of the totem pole PFC current inner-loop and introduces a PI control method based on dynamic root locus (DRL-PI). Experimental results on a 3 kW platform show that compared with traditional fixed parameter control, the proposed control method reduces the estimated total harmonic distortion (THD) by 0.74% in constant resistance experiment and 3.36% in constant voltage experiment.

Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 72%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.