An analytical solution for the secondary capacitor charging time of Tesla transformer with different optimal coupling coefficients

In the domain of high-voltage generation and pulsed power systems, Tesla transformers play a critical role, where the charging time of secondary capacitors fundamentally determines the design of system repetition frequency and control sequence optimization. To the best of our knowledge, this paper first presents an analytical solution for calculating the secondary capacitor charging time with different coupling coefficients. The analytical solution is applicable not only to Tesla transformers featuring open magnetic cores, where the coupling coefficient is close to 1, but also to air-core Tesla transformers with coupling coefficients of 0.6 or 0.385, which provides valuable guidance for designing high-voltage generation systems in related fields. Both numerical calculation experiments and circuit simulation experiments have confirmed the precision and broad applicability of the analytical solution derived in this paper.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-10-01
DOI
https://doi.org/10.1063/5.0284389
Primary Topic
Pulsed Power Technology Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An analytical solution for the secondary capacitor charging time of Tesla transformer with different optimal coupling coefficients

Zhiqiang Fan, Zuoxian Xiang, Jie Zhao, Wu Wang et al.
Review of Scientific Instruments
Pulsed Power Technology Applications
article

An analytical solution for the secondary capacitor charging time of Tesla transformer with different optimal coupling coefficients

Zhiqiang Fan, Zuoxian Xiang, Jie Zhao, Wu Wang, Kun Wei
article en

Abstract

In the domain of high-voltage generation and pulsed power systems, Tesla transformers play a critical role, where the charging time of secondary capacitors fundamentally determines the design of system repetition frequency and control sequence optimization. To the best of our knowledge, this paper first presents an analytical solution for calculating the secondary capacitor charging time with different coupling coefficients. The analytical solution is applicable not only to Tesla transformers featuring open magnetic cores, where the coupling coefficient is close to 1, but also to air-core Tesla transformers with coupling coefficients of 0.6 or 0.385, which provides valuable guidance for designing high-voltage generation systems in related fields. Both numerical calculation experiments and circuit simulation experiments have confirmed the precision and broad applicability of the analytical solution derived in this paper.

Review of Scientific InstrumentsVol. 96(10)
National Defence Academy (IN), Academy of Military Medical Sciences (CN)
Openalex Percentile: Top 65%
Pulsed Power Technology Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An analytical solution for the secondary capacitor charging time of Tesla transformer with different optimal coupling coefficients — Zhiqiang Fan, Zuoxian Xiang, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS