Non-Echo-Planar Versus Multishot Echo-Planar Diffusion-Weighted Imaging in Diagnosis of Suspected Cholesteatoma

Background:Cholesteatoma is a destructive middle ear lesion that can cause serious complications if not accurately detected, treated. Diffusion-weighted imaging (DWI) is standard noninvasive tool for diagnosis. We aimed to compare diagnostic performance of non-echo-planar (non-EPI) DWI , multishot echo-planar (EPI) DWI in patients with suspected cholesteatoma, using histopathology as gold standard. Methods:This cross-sectional study included 18 patients with clinically suspected cholesteatoma.All patients underwent both non-EPI,multishot EPI DWI sequences on a 1.5T scanner. Two blinded neuroradiologists independently assessed images, results were compared with intraoperative histopathological findings. Results:Mean lesion size was 108.1 ± 110.3 mm² with an average maximal diameter of 13.5 mm. Offensive otorrhea was most frequent symptom (61.1%), followed by loss of balance (50%) tinnitus (50%).Non-EPI DWI detected 14/16 histopathology-proven cholesteatomas (sensitivity 87.5%) and falsely classified 2/2 histopathology-negative cases as positive (specificity 0%); overall accuracy 77.8% and PPV 87.5% (p = 0.01). Median lesion size detected was 36.5 mm² (range 6–105). Interobserver agreement was moderate (κ = 0.52).Multishot EPI DWI classified 3/18 cases as positive; relative to histopathology this yielded 3 true positives, 0 false positives, 13 false negatives (2 true negatives): sensitivity = 18.8% (3/16), specificity = 100% (2/2), PPV = 100% (3/3), NPV = 13.3% (2/15), accuracy = 27.8% (5/18) (p = 0.50, not significant). Median lesion size was 45 mm² (range 30–60). Agreement with histopathology was poor (κ = 0.05) Conclusion:The present pilot study suggests that non-EPI DWI may offer superior sensitivity, diagnostic accuracy compared with multishot EPI DWI diagnosing middle ear cholesteatoma, particularly for small lesions.

Authors

Institutions

Publication Details

Journal
Zagazig University Medical Journal
Published
2025-10-01
DOI
https://doi.org/10.21608/zumj.2025.416136.4124
Primary Topic
Voice and Speech Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Echo-Planar Versus Multishot Echo-Planar Diffusion-Weighted Imaging in Diagnosis of Suspected Cholesteatoma

Heba Fathy Tantawy, Abdelrhman Mohamed Yousef, Mohammad Zakaryia Al-Azzazy, M. Saleh
Zagazig University Medical Journal
Voice and Speech Disorders
article

Non-Echo-Planar Versus Multishot Echo-Planar Diffusion-Weighted Imaging in Diagnosis of Suspected Cholesteatoma

Heba Fathy Tantawy, Abdelrhman Mohamed Yousef, Mohammad Zakaryia Al-Azzazy, M. Saleh
article en

Abstract

Background:Cholesteatoma is a destructive middle ear lesion that can cause serious complications if not accurately detected, treated. Diffusion-weighted imaging (DWI) is standard noninvasive tool for diagnosis. We aimed to compare diagnostic performance of non-echo-planar (non-EPI) DWI , multishot echo-planar (EPI) DWI in patients with suspected cholesteatoma, using histopathology as gold standard. Methods:This cross-sectional study included 18 patients with clinically suspected cholesteatoma.All patients underwent both non-EPI,multishot EPI DWI sequences on a 1.5T scanner. Two blinded neuroradiologists independently assessed images, results were compared with intraoperative histopathological findings. Results:Mean lesion size was 108.1 ± 110.3 mm² with an average maximal diameter of 13.5 mm. Offensive otorrhea was most frequent symptom (61.1%), followed by loss of balance (50%) tinnitus (50%).Non-EPI DWI detected 14/16 histopathology-proven cholesteatomas (sensitivity 87.5%) and falsely classified 2/2 histopathology-negative cases as positive (specificity 0%); overall accuracy 77.8% and PPV 87.5% (p = 0.01). Median lesion size detected was 36.5 mm² (range 6–105). Interobserver agreement was moderate (κ = 0.52).Multishot EPI DWI classified 3/18 cases as positive; relative to histopathology this yielded 3 true positives, 0 false positives, 13 false negatives (2 true negatives): sensitivity = 18.8% (3/16), specificity = 100% (2/2), PPV = 100% (3/3), NPV = 13.3% (2/15), accuracy = 27.8% (5/18) (p = 0.50, not significant). Median lesion size was 45 mm² (range 30–60). Agreement with histopathology was poor (κ = 0.05) Conclusion:The present pilot study suggests that non-EPI DWI may offer superior sensitivity, diagnostic accuracy compared with multishot EPI DWI diagnosing middle ear cholesteatoma, particularly for small lesions.

Zagazig University Medical JournalVol. 0(0)
Zagazig University (EG), Al-Azhar University (ID), Al Azhar University (QA)
Openalex Percentile: Top 65%
Voice and Speech Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.