Implementation and development of a DAQ system DELILA at ELI-NP
This paper reports the current status of the Data AcQuisition (DAQ) system in ELI-NP, Romania. The DAQ system uses several data-taking electronics modules, CAEN 1730 1725 and 1740 digitizer series, and Mesytec Analog-to-Digital Converter (ADC) and Time-to-Digital Converter (TDC). The DAQ system is able to acquire data from multiple detector types, such as PhotoMultiplier Tube (PMT) with scintillators, High Purity Ge (HPGe) detectors, and Si detectors. The DAQ system is constructed based on DAQ-Middleware, which makes the system flexible enough to be adapted to multiple experiments with minor source code modifications.
Authors
- S. Aogaki (ORCID: https://orcid.org/0000-0002-7950-3342)
- Ştefan Niculae
Institutions
- University of Bucharest (RO)
- Horia Hulubei National Institute for R and D in Physics and Nuclear Engineering (RO)
- Extreme Light Infrastructure - Nuclear Physics (RO)
Publication Details
- Journal
- EPJ Web of Conferences
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1051/epjconf/202533701156
- Citations
- 2
- Primary Topic
- Radiation Detection and Scintillator Technologies
- Type
- article
- Field-Weighted Citation Impact
- 3.77