AAPM task group 317 report: A joint AAPM and ESTRO report on brachytherapy catheter, needle, and applicator tracking technology

In recent years, various tracking technologies that work independently of imaging systems have been proposed to automate, simplify, and enhance various tasks in the brachytherapy treatment workflow. These tasks, critical to the overall accuracy of the therapeutic dose delivery, include applicator, catheter and needle insertion guidance, and reconstruction as well as transfer tube connection in afterloading technique. Task Group 317 was established as a joint American Association of Physicists in Medicine (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) committee to review: the current state-of-the-art scientific literature as it pertains to tracking technology in the field of brachytherapy; the benefits and issues related to the use of the technology for automated reconstruction of brachytherapy implants, quality control (QC) tasks such as channel path and tip reconstruction, and real-time guidance tasks; their limitations, in particular in the clinical environment and, finally, to develop recommendations related to commissioning, quality assurance (QA) and clinical use. The Task Group has looked in detail at key tracking technologies in advanced brachytherapy applications: infrared, electromagnetic, fiber optic shape sensing (fiber Bragg grating), and active radiofrequency coil tracking. For each, the performance and accuracy in well-controlled conditions as well as in clinically relevant environments are provided. Guidelines for clinical implementations, including target accuracy and performance needed for critical tasks, are summarized. Risk-based analysis is discussed in the context of an electromagnetic-based tracking system used as part of a clinical trial. The report concludes with the essential elements of an effective quality management program dedicated to the advanced features enabled by the above-described technology.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-10-01
DOI
https://doi.org/10.1002/mp.70037
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

AAPM task group 317 report: A joint AAPM and ESTRO report on brachytherapy catheter, needle, and applicator tracking technology

Robert Weersink, Yury Niatsetski, J. Adam M. Cunha, I‐Chow Hsu et al.
Medical Physics
Advanced Radiotherapy Techniques
article

AAPM task group 317 report: A joint AAPM and ESTRO report on brachytherapy catheter, needle, and applicator tracking technology

Robert Weersink, Yury Niatsetski, J. Adam M. Cunha, I‐Chow Hsu, Maxence Borot de Battisti, Marinus A. Moerland, Luc Beaulieu, Christopher L. Deufel, Christoph Bert, Kari Tanderup, Robert A. Cormack, Antonio L. Damato, Inger‐Karine K. Kolkman‐Deurloo, Gilion Hautvast
article en

Abstract

In recent years, various tracking technologies that work independently of imaging systems have been proposed to automate, simplify, and enhance various tasks in the brachytherapy treatment workflow. These tasks, critical to the overall accuracy of the therapeutic dose delivery, include applicator, catheter and needle insertion guidance, and reconstruction as well as transfer tube connection in afterloading technique. Task Group 317 was established as a joint American Association of Physicists in Medicine (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) committee to review: the current state-of-the-art scientific literature as it pertains to tracking technology in the field of brachytherapy; the benefits and issues related to the use of the technology for automated reconstruction of brachytherapy implants, quality control (QC) tasks such as channel path and tip reconstruction, and real-time guidance tasks; their limitations, in particular in the clinical environment and, finally, to develop recommendations related to commissioning, quality assurance (QA) and clinical use. The Task Group has looked in detail at key tracking technologies in advanced brachytherapy applications: infrared, electromagnetic, fiber optic shape sensing (fiber Bragg grating), and active radiofrequency coil tracking. For each, the performance and accuracy in well-controlled conditions as well as in clinically relevant environments are provided. Guidelines for clinical implementations, including target accuracy and performance needed for critical tasks, are summarized. Risk-based analysis is discussed in the context of an electromagnetic-based tracking system used as part of a clinical trial. The report concludes with the essential elements of an effective quality management program dedicated to the advanced features enabled by the above-described technology.

Medical PhysicsVol. 52(10)
NXP (Netherlands) (NL), Philips (Finland) (FI), Mayo Clinic (US), Memorial Sloan Kettering Cancer Center (US), University of California, San Francisco (US), Friedrich-Alexander-Universität Erlangen-Nürnberg (DE), University of Toronto (CA), Aarhus University (DK), Elekta (Switzerland) (CH), University Medical Center Utrecht (NL), Universitätsklinikum Erlangen (DE), Hôtel-Dieu de Québec (CA), Philips (Netherlands) (NL), Mayo Clinic in Arizona (US), Parallel Consulting (United States) (US), Danish Pain Research Center (DK), Mayo Clinic in Florida (US), Erasmus MC Cancer Institute (NL), Dana-Farber Brigham Cancer Center (US)
Openalex Percentile: Top 63%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.