Evaluating artificial intelligence algorithms for the standardization of transtibial prosthetic socket shape design

The quality of a transtibial prosthetic socket depends on the prosthetist’s skills and expertise, as the fitting is performed manually. This study investigates multiple artificial intelligence (AI) approaches to help standardize transtibial prosthetic socket design. Data from 118 patients were collected by prosthetists working in the Dutch healthcare system. This data consists of a three-dimensional (3D) scan of the residual limb and a corresponding 3D model of the prosthetist-designed socket. Multiple data pre-processing steps are performed for alignment, standardization and optionally compression using Morphable Models and Principal Component Analysis. Afterward, three different algorithms - a 3D neural network, Feedforward neural network, and random forest - are developed to either predict (1) the final socket shape or (2) the adaptations performed by a prosthetist to predict the socket shape based on the 3D scan of the residual limb. Each algorithm’s performance was evaluated by comparing the prosthetist-designed socket with the AI-generated socket, using two metrics in combination with the error location. First, we measure the surface-to-surface distance to assess the overall surface error between the AI-generated socket and the prosthetist-designed socket. Second, distance maps between the AI-generated and prosthetist sockets are utilized to analyze the error’s location. For all algorithms, estimating the required adaptations outperformed direct prediction of the final socket shape. The random forest model applied to adaptation prediction yields the lowest error with a median surface-to-surface distance of 1.24 mm, a first quartile of 1.03 mm, and a third quartile of 1.54 mm. • Built novel methods using PCA and 3D AI for transtibial prosthetic sockets. • Compared multiple algorithms and data representations on performance. • The random forest predicting the necessary adaptations has the lowest error.

Authors

Institutions

Publication Details

Journal
Computer Methods and Programs in Biomedicine Update
Published
2026-04-18
DOI
https://doi.org/10.1016/j.cmpbup.2026.100249
Primary Topic
Manufacturing Process and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating artificial intelligence algorithms for the standardization of transtibial prosthetic socket shape design

Ruud A. Leijendekkers, Thomas J. J. Maal, Tal Kachman, Merel van der Stelt et al.
Computer Methods and Programs in Biomedicine Update
Manufacturing Process and Optimization
article

Evaluating artificial intelligence algorithms for the standardization of transtibial prosthetic socket shape design

Ruud A. Leijendekkers, Thomas J. J. Maal, Tal Kachman, Merel van der Stelt, Guido de Jong, Christoff Jordaan, V. M. A. Stirler
article en

Abstract

The quality of a transtibial prosthetic socket depends on the prosthetist’s skills and expertise, as the fitting is performed manually. This study investigates multiple artificial intelligence (AI) approaches to help standardize transtibial prosthetic socket design. Data from 118 patients were collected by prosthetists working in the Dutch healthcare system. This data consists of a three-dimensional (3D) scan of the residual limb and a corresponding 3D model of the prosthetist-designed socket. Multiple data pre-processing steps are performed for alignment, standardization and optionally compression using Morphable Models and Principal Component Analysis. Afterward, three different algorithms - a 3D neural network, Feedforward neural network, and random forest - are developed to either predict (1) the final socket shape or (2) the adaptations performed by a prosthetist to predict the socket shape based on the 3D scan of the residual limb. Each algorithm’s performance was evaluated by comparing the prosthetist-designed socket with the AI-generated socket, using two metrics in combination with the error location. First, we measure the surface-to-surface distance to assess the overall surface error between the AI-generated socket and the prosthetist-designed socket. Second, distance maps between the AI-generated and prosthetist sockets are utilized to analyze the error’s location. For all algorithms, estimating the required adaptations outperformed direct prediction of the final socket shape. The random forest model applied to adaptation prediction yields the lowest error with a median surface-to-surface distance of 1.24 mm, a first quartile of 1.03 mm, and a third quartile of 1.54 mm. • Built novel methods using PCA and 3D AI for transtibial prosthetic sockets. • Compared multiple algorithms and data representations on performance. • The random forest predicting the necessary adaptations has the lowest error.

Computer Methods and Programs in Biomedicine UpdateVol. 9
Radboud University Nijmegen (NL), Radboud University Medical Center (NL), Ministry of Defence (BR)
ZonMw
Openalex Percentile: Top 100%
Manufacturing Process and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.