Design study of sound insulation structure for power equipment based on multi-resonance

Aiming at the problem of controlling low-frequency line spectrum noise of power equipment, this paper designs a sound insulation structure by combining Helmholtz resonance and dynamic vibration absorption technologies. By optimizing the parameters of the Helmholtz resonator, it is matched with the main noise frequencies of 100 Hz, 200 Hz, 300 Hz and 400 Hz to achieve efficient sound insulation at specific frequencies. The natural frequency of the dynamic vibration absorber is designed and optimized to accurately match the main noise frequencies so as to reduce vibration energy. After combining the two technologies, the sound insulation performance is significantly improved, with the sound insulation quantities at 100 Hz, 200 Hz, 300 Hz and 400 Hz reaching 149.7 dB, 196.88 dB, 172.14 dB and 169.97 dB respectively, which verifies the effectiveness of the multi-resonance sound insulation structure in controlling low-frequency noise of power equipment.

Authors

Publication Details

Journal
Vibroengineering PROCEDIA
Published
2025-09-30
DOI
https://doi.org/10.21595/vp.2025.25229
Citations
1
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design study of sound insulation structure for power equipment based on multi-resonance

Z. Zang, R Liu, Gang Fan, Endong Wang et al.
1 citations
Vibroengineering PROCEDIA
Acoustic Wave Phenomena Research
0.67
article

Design study of sound insulation structure for power equipment based on multi-resonance

Z. Zang, R Liu, Gang Fan, Endong Wang, Yachen Wang
article en
1 citations

Abstract

Aiming at the problem of controlling low-frequency line spectrum noise of power equipment, this paper designs a sound insulation structure by combining Helmholtz resonance and dynamic vibration absorption technologies. By optimizing the parameters of the Helmholtz resonator, it is matched with the main noise frequencies of 100 Hz, 200 Hz, 300 Hz and 400 Hz to achieve efficient sound insulation at specific frequencies. The natural frequency of the dynamic vibration absorber is designed and optimized to accurately match the main noise frequencies so as to reduce vibration energy. After combining the two technologies, the sound insulation performance is significantly improved, with the sound insulation quantities at 100 Hz, 200 Hz, 300 Hz and 400 Hz reaching 149.7 dB, 196.88 dB, 172.14 dB and 169.97 dB respectively, which verifies the effectiveness of the multi-resonance sound insulation structure in controlling low-frequency noise of power equipment.

Vibroengineering PROCEDIAVol. 59
Openalex Percentile: Top 26%
Acoustic Wave Phenomena Research
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.