In vivo analysis of active versus self-tapping implants with SLA surface treatment

Surface modifications and implant thread designs play a crucial role in achieving primary stability and osseointegration. Therefore, it is of interest to compare the short-term clinical and radiographic outcomes of active versus self-tapping titanium implants with sandblasted, large-grit, acid-etched (SLA) surfaces in 20 systemically healthy patients requiring posterior implant-supported prostheses. Clinical and radiographic parameters were assessed at 4, 7, 12 and 26 weeks and statistical analysis showed significant intra-group improvements in probing depth, attachment levels, mucosal margin stability and bone gain. However, intergroup comparisons at all-time points revealed no statistically significant differences, indicating comparable performance between the two implant designs. Overall, both active and self-threaded SLA implants demonstrated favorable short-term clinical outcomes, supporting their effectiveness in promoting early osseointegration and potential use in early loading protocols.

Authors

Institutions

Publication Details

Journal
Bioinformation
Published
2025-09-30
DOI
https://doi.org/10.6026/973206300213152
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In vivo analysis of active versus self-tapping implants with SLA surface treatment

E. Vidya Sravanthi, B Archana, D Vidhyadhar, Guru Charan Karthik K.V et al.
Bioinformation
Bone Tissue Engineering Materials
article

In vivo analysis of active versus self-tapping implants with SLA surface treatment

E. Vidya Sravanthi, B Archana, D Vidhyadhar, Guru Charan Karthik K.V, Prathyusha Pulleti, Kiran Kunwar Rathore
article en

Abstract

Surface modifications and implant thread designs play a crucial role in achieving primary stability and osseointegration. Therefore, it is of interest to compare the short-term clinical and radiographic outcomes of active versus self-tapping titanium implants with sandblasted, large-grit, acid-etched (SLA) surfaces in 20 systemically healthy patients requiring posterior implant-supported prostheses. Clinical and radiographic parameters were assessed at 4, 7, 12 and 26 weeks and statistical analysis showed significant intra-group improvements in probing depth, attachment levels, mucosal margin stability and bone gain. However, intergroup comparisons at all-time points revealed no statistically significant differences, indicating comparable performance between the two implant designs. Overall, both active and self-threaded SLA implants demonstrated favorable short-term clinical outcomes, supporting their effectiveness in promoting early osseointegration and potential use in early loading protocols.

BioinformationVol. 21(09)
Indian Army (IN), Pain Relief and Palliative Care Society (IN), MNR Dental College and Hospital (IN), University of Maryland, Baltimore County (US), Kamineni Institute of Dental Sciences (IN)
Openalex Percentile: Top 73%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.