INDOOR AND OUTDOOR AIR QUALITY: ANALYSIS OF SUSPENDED PARTICLES IN RESIDENTIAL SPACES IN BOR, SERBIA

This study examines the levels of suspended particles (PM10 and PM2.5) in residential settings in Bor, Serbia, alongside simultaneous outdoor measurements of PM. The project lasts 2 years and involves 30 apartments per year, selected based on criteria such as window type, connection to central heating, non-smoking status, distance from major pollution sources, and prevailing wind direction. Results from the winter measurement campaign (heating season) in 15 apartments, presented here, show that indoor PM concentrations vary significantly depending on ventilation habits, window type, and proximity to pollution sources. Measurements were conducted over 45 days during the heating season, and residents maintained activity diaries to document household activities. The average PM10 concentration in apartments was 18.2 µg/m³, while the average PM2.5 concentration was 12.0 µg/m³. The average indoor/outdoor concentration ratio was 0.58 for PM10 and 0.68 for PM2.5. The final results of this project will support the development of recommendations aimed at reducing indoor air pollution in urban homes across Serbia.

Authors

Publication Details

Published
2025-01-01
DOI
https://doi.org/10.46793/semsie25.241t
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

INDOOR AND OUTDOOR AIR QUALITY: ANALYSIS OF SUSPENDED PARTICLES IN RESIDENTIAL SPACES IN BOR, SERBIA

Viša Tasić
Air Quality Monitoring and Forecasting
article

INDOOR AND OUTDOOR AIR QUALITY: ANALYSIS OF SUSPENDED PARTICLES IN RESIDENTIAL SPACES IN BOR, SERBIA

Viša Tasić
article en

Abstract

This study examines the levels of suspended particles (PM10 and PM2.5) in residential settings in Bor, Serbia, alongside simultaneous outdoor measurements of PM. The project lasts 2 years and involves 30 apartments per year, selected based on criteria such as window type, connection to central heating, non-smoking status, distance from major pollution sources, and prevailing wind direction. Results from the winter measurement campaign (heating season) in 15 apartments, presented here, show that indoor PM concentrations vary significantly depending on ventilation habits, window type, and proximity to pollution sources. Measurements were conducted over 45 days during the heating season, and residents maintained activity diaries to document household activities. The average PM10 concentration in apartments was 18.2 µg/m³, while the average PM2.5 concentration was 12.0 µg/m³. The average indoor/outdoor concentration ratio was 0.58 for PM10 and 0.68 for PM2.5. The final results of this project will support the development of recommendations aimed at reducing indoor air pollution in urban homes across Serbia.

Erasmus+
Openalex Percentile: Top 75%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

INDOOR AND OUTDOOR AIR QUALITY: ANALYSIS OF SUSPENDED PARTICLES IN RESIDENTIAL SPACES IN BOR, SERBIA — Viša Tasić · (2025) | TGRS Research Map | TGRS