Thermal design and CFD simulation of an internal heat exchanger with R1234yf as an alternate refrigerant to R134a

The most widely utilized refrigerant in car air conditioners today is still R134a, particularly in developing nations, but its global warming potential is very high (1430).The use of high global warming potential working substances is progressively prohibited and restricted by the F-gas act and the Kigali Amendment in developing and developed nations.R1234yf has been the subject of thermodynamic research as a potential replacement for R134a in vehicle air conditioning systems.Compared to R134a, R1234yf performs somewhat inferior, that can be improved by incorporating an internal heat exchanger into the existing system.Refereeing to the literature available, computational fluid dynamics analysis of the internal heat exchanger for an automobile air conditioning system with refrigerant R1234yf is rarely observed.Hence the novel concept of computational fluid dynamics analysis of thermally designed internal heat exchanger is focused here.This study analyzes the thermal design of an internal heat exchanger and its impact on the coefficient of performance for R1234yf and R134a.And computational fluid dynamics analysis of the thermal designed internal heat exchanger is performed to finalize the dimension of the internal heat exchanger.For similar cooling capacity, the system with refrigerant R134a performance is not much affected by the application of an internal heat exchanger.Its COP increases from 3.636 to 3.676, i.e., only 1.09%.While the performance gap of the system with refrigerant R1234yf as compared to the system with R134a without an internal heat exchanger is 5.17%, while the gap is decreased up to 3.16% with an internal heat exchanger.Identical results are obtained in computational fluid dynamics analysis, with an increment in the internal heat exchanger length, heat transfer increases as well, and the outlet temperature meets the necessary level within a tolerable pressure drop.

Authors

Publication Details

Journal
Journal of Thermal Engineering
Published
2025-01-01
DOI
https://doi.org/10.14744/thermal.0000998
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal design and CFD simulation of an internal heat exchanger with R1234yf as an alternate refrigerant to R134a

Bharat Patel
Journal of Thermal Engineering
Refrigeration and Air Conditioning Technologies
article

Thermal design and CFD simulation of an internal heat exchanger with R1234yf as an alternate refrigerant to R134a

Bharat Patel
article en

Abstract

The most widely utilized refrigerant in car air conditioners today is still R134a, particularly in developing nations, but its global warming potential is very high (1430).The use of high global warming potential working substances is progressively prohibited and restricted by the F-gas act and the Kigali Amendment in developing and developed nations.R1234yf has been the subject of thermodynamic research as a potential replacement for R134a in vehicle air conditioning systems.Compared to R134a, R1234yf performs somewhat inferior, that can be improved by incorporating an internal heat exchanger into the existing system.Refereeing to the literature available, computational fluid dynamics analysis of the internal heat exchanger for an automobile air conditioning system with refrigerant R1234yf is rarely observed.Hence the novel concept of computational fluid dynamics analysis of thermally designed internal heat exchanger is focused here.This study analyzes the thermal design of an internal heat exchanger and its impact on the coefficient of performance for R1234yf and R134a.And computational fluid dynamics analysis of the thermal designed internal heat exchanger is performed to finalize the dimension of the internal heat exchanger.For similar cooling capacity, the system with refrigerant R134a performance is not much affected by the application of an internal heat exchanger.Its COP increases from 3.636 to 3.676, i.e., only 1.09%.While the performance gap of the system with refrigerant R1234yf as compared to the system with R134a without an internal heat exchanger is 5.17%, while the gap is decreased up to 3.16% with an internal heat exchanger.Identical results are obtained in computational fluid dynamics analysis, with an increment in the internal heat exchanger length, heat transfer increases as well, and the outlet temperature meets the necessary level within a tolerable pressure drop.

Journal of Thermal Engineering
Science and Engineering Research Board
Openalex Percentile: Top 71%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Thermal design and CFD simulation of an internal heat exchanger with R1234yf as an alternate refrigerant to R134a — Bharat Patel · Journal of Thermal Engineering (2025) | TGRS Research Map | TGRS