Practical primary thermometry via alkali-metal-vapour Doppler broadening

Doppler-broadening thermometry (DBT) can be used as a calibration-free primary thermometer suitable for practical applications, e.g. reliably measuring temperatures over long periods of time in environments where sensor retrieval for recalibration is impractical. We report on our proof-of-concept investigations into DBT with alkali-metal-vapour cells, with a particular focus on both absorption and frequency accuracy during scans. We reach sub-kelvin temperature accuracy, and experimental absorption-fit residuals below 0.05%, in a simple set-up. The outlook for portable, practical devices is bright, with clear prospects for future improvement. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Authors

Institutions

Publication Details

Journal
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Published
2026-01-15
DOI
https://doi.org/10.1098/rsta.2024.0455
Citations
1
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
104.69
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical primary thermometry via alkali-metal-vapour Doppler broadening

Erling Riis, Graham Machin, Aidan S. Arnold, Nicola Agnew et al.
1 citations
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
Calibration and Measurement Techniques
104.69
article

Practical primary thermometry via alkali-metal-vapour Doppler broadening

Erling Riis, Graham Machin, Aidan S. Arnold, Nicola Agnew, Veronika Vohníková
article en
1 citations

Abstract

Doppler-broadening thermometry (DBT) can be used as a calibration-free primary thermometer suitable for practical applications, e.g. reliably measuring temperatures over long periods of time in environments where sensor retrieval for recalibration is impractical. We report on our proof-of-concept investigations into DBT with alkali-metal-vapour cells, with a particular focus on both absorption and frequency accuracy during scans. We reach sub-kelvin temperature accuracy, and experimental absorption-fit residuals below 0.05%, in a simple set-up. The outlook for portable, practical devices is bright, with clear prospects for future improvement. This article is part of the Theo Murphy meeting issue 'The redefined kelvin: progress and prospects'.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering SciencesVol. 384(2312)
University of Strathclyde (GB), CSIR National Physical Laboratory of India (IN)
Openalex Percentile: Top 1%
Calibration and Measurement Techniques
104.69
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.