An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals

Bioradar-based Electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for non-contact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high Signal-to-Noise Ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 μVpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler Heartbeat Diagram (DHD) signals. Finally, we introduced a lightweight UNet-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving Root Mean Squared Error (RMSE) values of 0.160 and 0.330, Root Mean Absolute Error (RMAE) values of 0.261 and 0.400, and Pearson Correlation Coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04M parameters, Floating-Point Operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s per execution, and low power consumption of 379.5mW. Moreover, it requires just 29.13MB of Random Access Memory (RAM) and 10.49MB of Read-Only Memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both a public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for non-contact healthcare and medical applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3617402
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals

Kun Qian, Mingqi Zhao, Qinglin Zhao, Fuze Tian et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
ECG Monitoring and Analysis
1.39
article

An Onboard Executable Multitask Network Model for Bioradar-Based ECG Signal Reconstruction Using High-Fidelity DHD Signals

Kun Qian, Mingqi Zhao, Qinglin Zhao, Fuze Tian, Björn W. Schuller, Jingyu Liu, Yoshiharu Yamamoto, Bin Hu, Jie Liu, Haojie Zhang
article en
1 citations

Abstract

Bioradar-based Electrocardiogram (ECG) reconstruction shows great promise in replacing traditional contact-based ECG collection methods for non-contact, long-term healthcare applications, such as continuous cardiorespiratory disease monitoring and early warning systems. In this work, we first designed a practical bioradar system for high Signal-to-Noise Ratio (SNR) I/Q baseband signal acquisition, achieving excellent performance with background noise not exceeding 3.18 μVpp and SNRs ranging from 26 to 119 dB. Next, we developed a high-linearity arctangent demodulation method to extract high-fidelity Doppler Heartbeat Diagram (DHD) signals. Finally, we introduced a lightweight UNet-based multitask network model for ECG signal reconstruction, which demonstrated performance achieving Root Mean Squared Error (RMSE) values of 0.160 and 0.330, Root Mean Absolute Error (RMAE) values of 0.261 and 0.400, and Pearson Correlation Coefficient (PCC) values of 95.17% and 85.26% for two different datasets, respectively. This model is characterized by low computational complexity, with 7.04M parameters, Floating-Point Operations (FLOPs) of 889.16 M, real-time processing speed of 1.05 s per execution, and low power consumption of 379.5mW. Moreover, it requires just 29.13MB of Random Access Memory (RAM) and 10.49MB of Read-Only Memory (ROM), making it highly suitable for deployment in embedded systems. Experimental results from both a public dataset and our own dataset show that the proposed lightweight ECG reconstruction model, when combined with the designed high-fidelity DHD signal acquisition bioradar system, holds significant potential for non-contact healthcare and medical applications.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Beijing Institute of Technology (CN), Japan Graduate School of Education University (JP), Aerospace Center Hospital (CN), Ministry of Science and Technology (VN), Xuzhou Construction Machinery Group (China) (CN), Imperial College London (GB), The University of Tokyo (JP), Lanzhou University (CN)
Openalex Percentile: Top 14%
ECG Monitoring and Analysis
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.