Power Quality Enhancement in Standalone DFIG-Based Wind Farms Using E2PLL-Controlled D-Statcom

Independent wind farms with Doubly Fed Induction Generators (DFIGs) often experience major overvoltage, harmonic distortion, and other power quality concerns, as well as transient disturbances [1]. This study implements a D-STATCOM system combined with Phase-Locked Loop (PLL) control to address voltage stability and enhance dynamic reactive power compensation [2]. The PLL-based control locks the system voltage, enabling synchronous operation and effective harmonic filtering [2]. A phase controller is incorporated within the D-STATCOM to further improve system response to increase damping against frequency variations and slow voltage magnitude changes. The created system is modeled in the MATLAB/Simulink platform, simulated, with the capability of DFIG-based wind farms to reduce power quality issues studied. Results demonstrate significant improvements in voltage stability, a marked reduction in harmonic content, and enhanced overall power quality performance [3]. These findings reinforce the potential of advanced D-STATCOM configurations in supporting reliable, high-quality power delivery from independent renewable energy sources [4].

Publication Details

Journal
International Journal of Electrical and Electronics Engineering
Published
2025-09-30
DOI
https://doi.org/10.14445/23488379/ijeee-v12i9p111
Primary Topic
Energy Load and Power Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Quality Enhancement in Standalone DFIG-Based Wind Farms Using E2PLL-Controlled D-Statcom

International Journal of Electrical and Electronics Engineering
Energy Load and Power Forecasting
article

Power Quality Enhancement in Standalone DFIG-Based Wind Farms Using E2PLL-Controlled D-Statcom

article en

Abstract

Independent wind farms with Doubly Fed Induction Generators (DFIGs) often experience major overvoltage, harmonic distortion, and other power quality concerns, as well as transient disturbances [1]. This study implements a D-STATCOM system combined with Phase-Locked Loop (PLL) control to address voltage stability and enhance dynamic reactive power compensation [2]. The PLL-based control locks the system voltage, enabling synchronous operation and effective harmonic filtering [2]. A phase controller is incorporated within the D-STATCOM to further improve system response to increase damping against frequency variations and slow voltage magnitude changes. The created system is modeled in the MATLAB/Simulink platform, simulated, with the capability of DFIG-based wind farms to reduce power quality issues studied. Results demonstrate significant improvements in voltage stability, a marked reduction in harmonic content, and enhanced overall power quality performance [3]. These findings reinforce the potential of advanced D-STATCOM configurations in supporting reliable, high-quality power delivery from independent renewable energy sources [4].

International Journal of Electrical and Electronics EngineeringVol. 12(9)
Openalex Percentile: Top 73%
Energy Load and Power Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.