From novice to proficient: Comparing veterinary student learning curves of tonometry using TonoPen, TonoVet and TonoVet Plus

Our aim was to compare learning curves of final year veterinary students using three commonly-used tonometers for measuring intraocular pressure (IOP) in dogs: TonoPen XL (TP), TonoVet (TV), and TonoVet Plus (TVP). Students were randomly assigned to use one of the tonometers, and their performance metrics (IOP readings, number of attempts and time required to obtain a valid reading) were recorded over a one-week period and compared to those of experienced clinicians. Tonometry data were analyzed using linear mixed-effects models, and student-clinician IOP agreement was assessed using intraclass correlation coefficients (ICC). In the TVP group (n = 39), students took the longest to measure (+9.1 s compared to clinicians, p < 0.001), showed a non-significant trend toward time improvement (reduction ≤0.5 s/test, p ≥ 0.095), and demonstrated the highest agreement with clinicians (ICC = 0.71). In the TV group (n = 38), students took longer to measure than with TP and less time than with TVP (+6.9 s, p < 0.001) but had significant improvement in measurement time (reduction of 1.03 s/test, p = 0.023) and moderate agreement (ICC = 0.68). In the TP group (n = 37), students were fastest (+5.7 s, p < 0.001) and required fewer attempts to obtain valid readings (reduction of 0.056 attempts/eye, p = 0.015), though this group had the lowest student-clinician agreement (ICC = 0.53). Our results show that student performance improved with all tonometers. TP demonstrated the shortest learning curve but had the poorest agreement with clinician measurements. TVP yielded the best agreement but required a longer learning curve. TV offered a balance between learning curve and measurement consistency. These findings highlight the distinct learning characteristics of each device and can improve targeted training strategies in veterinary education.

Authors

Institutions

Publication Details

Journal
Research in Veterinary Science
Published
2025-09-27
DOI
https://doi.org/10.1016/j.rvsc.2025.105906
Citations
1
Primary Topic
Veterinary Practice and Education Studies
Type
article
Field-Weighted Citation Impact
3.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From novice to proficient: Comparing veterinary student learning curves of tonometry using TonoPen, TonoVet and TonoVet Plus

Ron Ofri, Karin W. Handel, Oren Pe’er, Dikla Arad et al.
1 citations
Research in Veterinary Science
Veterinary Practice and Education Studies
3.12
article

From novice to proficient: Comparing veterinary student learning curves of tonometry using TonoPen, TonoVet and TonoVet Plus

Ron Ofri, Karin W. Handel, Oren Pe’er, Dikla Arad, Lionel Sebbag, Yamit Soueid, Bar Fruchter, N. Aharon
article en
1 citations

Abstract

Our aim was to compare learning curves of final year veterinary students using three commonly-used tonometers for measuring intraocular pressure (IOP) in dogs: TonoPen XL (TP), TonoVet (TV), and TonoVet Plus (TVP). Students were randomly assigned to use one of the tonometers, and their performance metrics (IOP readings, number of attempts and time required to obtain a valid reading) were recorded over a one-week period and compared to those of experienced clinicians. Tonometry data were analyzed using linear mixed-effects models, and student-clinician IOP agreement was assessed using intraclass correlation coefficients (ICC). In the TVP group (n = 39), students took the longest to measure (+9.1 s compared to clinicians, p < 0.001), showed a non-significant trend toward time improvement (reduction ≤0.5 s/test, p ≥ 0.095), and demonstrated the highest agreement with clinicians (ICC = 0.71). In the TV group (n = 38), students took longer to measure than with TP and less time than with TVP (+6.9 s, p < 0.001) but had significant improvement in measurement time (reduction of 1.03 s/test, p = 0.023) and moderate agreement (ICC = 0.68). In the TP group (n = 37), students were fastest (+5.7 s, p < 0.001) and required fewer attempts to obtain valid readings (reduction of 0.056 attempts/eye, p = 0.015), though this group had the lowest student-clinician agreement (ICC = 0.53). Our results show that student performance improved with all tonometers. TP demonstrated the shortest learning curve but had the poorest agreement with clinician measurements. TVP yielded the best agreement but required a longer learning curve. TV offered a balance between learning curve and measurement consistency. These findings highlight the distinct learning characteristics of each device and can improve targeted training strategies in veterinary education.

Research in Veterinary ScienceVol. 196
Hebrew University of Jerusalem (IL)
Openalex Percentile: Top 7%
Veterinary Practice and Education Studies
3.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.