On-chip integration of electromembrane extraction and thin-film solid-phase microextraction using polyaniline/graphene oxide composite for determination of synthetic dyes in beverage and environmental samples

In this study, an integration of on-chip electromembrane extraction (EME) and thin-film solid-phase microextraction (TF-SPME) was developed for the determination of cationic synthetic dyes, including methylene blue, malachite green, and rhodamine B in beverage and environmental samples. The device consisted of two separate chambers: one for the sample solution (donor phase) and one for acceptor phase. A conductive thin-film of polyaniline/graphene oxide (PANI/GO) nanocomposites was deposited electrochemically on a fluorine-doped tin oxide surface, which served as the TF-SPME sorbent and electrode in the acceptor chamber. During extraction, target analytes migrated under an electric field and were simultaneously adsorbed onto the PANI/GO coating. A desorption solvent was subsequently introduced into the acceptor phase to elute the analytes, which was analyzed by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of the key parameters affecting the extraction was carried out to maximize the efficiency. Under optimal conditions, limits of detection in the range of 1.5-3 μg L<sup>-1</sup> were achieved. The method exhibited linearity within 10-1000 μg L<sup>-1</sup> for malachite green and 5-1000 μg L<sup>-1</sup> for methylene blue and rhodamine B (<i>R</i><sup>2</sup> ≥ 0.9963). The applicability of the proposed technique was evaluated by determining the model analytes in grape juice, fish farming river water, and textile industry wastewater, yielding relative recoveries ranging from 96.5% to 116.8%. Consequently, the integration of EME/TF-SPME and the use of PANI/GO in the acceptor phase were found to be successful in determination of cationic dyes in environmental samples.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay01427a
Primary Topic
Dye analysis and toxicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-chip integration of electromembrane extraction and thin-film solid-phase microextraction using polyaniline/graphene oxide composite for determination of synthetic dyes in beverage and environmental samples

Razieh Zamani, Yadollah Yamini, Simin Darabi
Analytical Methods
Dye analysis and toxicity
article

On-chip integration of electromembrane extraction and thin-film solid-phase microextraction using polyaniline/graphene oxide composite for determination of synthetic dyes in beverage and environmental samples

Razieh Zamani, Yadollah Yamini, Simin Darabi
article en

Abstract

In this study, an integration of on-chip electromembrane extraction (EME) and thin-film solid-phase microextraction (TF-SPME) was developed for the determination of cationic synthetic dyes, including methylene blue, malachite green, and rhodamine B in beverage and environmental samples. The device consisted of two separate chambers: one for the sample solution (donor phase) and one for acceptor phase. A conductive thin-film of polyaniline/graphene oxide (PANI/GO) nanocomposites was deposited electrochemically on a fluorine-doped tin oxide surface, which served as the TF-SPME sorbent and electrode in the acceptor chamber. During extraction, target analytes migrated under an electric field and were simultaneously adsorbed onto the PANI/GO coating. A desorption solvent was subsequently introduced into the acceptor phase to elute the analytes, which was analyzed by high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of the key parameters affecting the extraction was carried out to maximize the efficiency. Under optimal conditions, limits of detection in the range of 1.5-3 μg L<sup>-1</sup> were achieved. The method exhibited linearity within 10-1000 μg L<sup>-1</sup> for malachite green and 5-1000 μg L<sup>-1</sup> for methylene blue and rhodamine B (<i>R</i><sup>2</sup> ≥ 0.9963). The applicability of the proposed technique was evaluated by determining the model analytes in grape juice, fish farming river water, and textile industry wastewater, yielding relative recoveries ranging from 96.5% to 116.8%. Consequently, the integration of EME/TF-SPME and the use of PANI/GO in the acceptor phase were found to be successful in determination of cationic dyes in environmental samples.

Analytical MethodsVol. 17(40)
Tarbiat Modares University (IR)
Openalex Percentile: Top 69%
Dye analysis and toxicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-chip integration of electromembrane extraction and thin-film solid-phase microextraction using polyaniline/graphene oxide composite for determination of synthetic dyes in beverage and environmental samples — Razieh Zamani, Yadollah Yamini, et al. · Analytical Methods (2025) | TGRS Research Map | TGRS