Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure

Fluid extravasation is a prominent feature of several disease processes in acute and critical illness. Bioimpedance at frequencies representing extracellular and total resistance offers an opportunity to monitor fluid shifts. The aim of the present study was to explore if a novel wearable bioimpedance device could monitor fluid shifts during lower body negative pressure (LBNP). Eleven subjects underwent 40 min of LBNP at 30 mmHg. Bioimpedance was measured on the leg, upper back, and thoracic midaxillary line. Changes in resistance were compared using mixed linear regression. Further, hemoglobin and albumin concentrations were measured. Ten subjects completed the protocol. Compared to baseline, both extracellular and total resistance changed to the end of the LBNP exposure at all measurement sites. The mean extracellular resistance changed as follows: leg -6.6% (SD 3.1; p < 0.001), upper back 4.1% (SD 3.5; p < 0.001), and midaxillary line 6.3% (SD 2.8; p < 0.001). The wearable bioimpedance sensor detected the expected extracellular fluid shifts occurring with LBNP. Further clinical studies to explore if fluid extravasation in common pathologic conditions can be measured are warranted.

Authors

Institutions

Publication Details

Journal
Physiological Reports
Published
2025-10-01
DOI
https://doi.org/10.14814/phy2.70603
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure

Lars Øivind Høiseth, Sigve Nyvik, Harald Noddeland, Anne Thorud et al.
Physiological Reports
Hemodynamic Monitoring and Therapy
article

Wearable and noninvasive monitoring of fluid shifts: A pilot study assessing a novel bioimpedance sensor during lower body negative pressure

Lars Øivind Høiseth, Sigve Nyvik, Harald Noddeland, Anne Thorud, Frida Bremnes
article en

Abstract

Fluid extravasation is a prominent feature of several disease processes in acute and critical illness. Bioimpedance at frequencies representing extracellular and total resistance offers an opportunity to monitor fluid shifts. The aim of the present study was to explore if a novel wearable bioimpedance device could monitor fluid shifts during lower body negative pressure (LBNP). Eleven subjects underwent 40 min of LBNP at 30 mmHg. Bioimpedance was measured on the leg, upper back, and thoracic midaxillary line. Changes in resistance were compared using mixed linear regression. Further, hemoglobin and albumin concentrations were measured. Ten subjects completed the protocol. Compared to baseline, both extracellular and total resistance changed to the end of the LBNP exposure at all measurement sites. The mean extracellular resistance changed as follows: leg -6.6% (SD 3.1; p < 0.001), upper back 4.1% (SD 3.5; p < 0.001), and midaxillary line 6.3% (SD 2.8; p < 0.001). The wearable bioimpedance sensor detected the expected extracellular fluid shifts occurring with LBNP. Further clinical studies to explore if fluid extravasation in common pathologic conditions can be measured are warranted.

Physiological ReportsVol. 13(19)
Oslo University Hospital (NO), University of Oslo (NO), Ship Modelling & Simulation Centre (NO)
Norges Forskningsråd
Openalex Percentile: Top 56%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.