Detection of Typical and Blast Cells in Acute and Chronic Leukaemia Using the Manual Method and Hematology Analyzer BC-720

Introduction: Diagnosing Leukaemia requires precise identification of atypical whiteblood cells. This research aims to compare the effectiveness of the BC-720 analyzerand manual microscopy in identifying blast and typical cells in both acute and chronicLeukaemia. Manual microscopy and the BC-720 analyzer were used to investigatedifferential white blood cell counts from 68 Leukaemia patients and 18 controls.Sensitivity and error rates for detecting abnormal cells were evaluated. The manualapproach had a recognition loss of 12%, but successfully identified 47.1% of cases. TheBC-720 identified 52.9% of cases, with higher detection rates in chronic patients(41.2%) and control cases (5.9%). In acute cases, the detection loss was 8.0% lower.Both methods showed advantages and limitations. The BC-720 demonstrated higherdetection rates for abnormal cells, particularly in acute Leukaemia, and lowerrecognition losses compared to manual microscopy. It can aid in more accurateLeukaemia classification and management.

Authors

Institutions

Publication Details

Journal
Misurata Medical Sciences Journal
Published
2025-06-24
DOI
https://doi.org/10.36602/mmsj/2023.n09.06
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Typical and Blast Cells in Acute and Chronic Leukaemia Using the Manual Method and Hematology Analyzer BC-720

Maher Matar, Mehmed M. Bakhtaran, Malak M. Keiba
Misurata Medical Sciences Journal
Digital Imaging for Blood Diseases
article

Detection of Typical and Blast Cells in Acute and Chronic Leukaemia Using the Manual Method and Hematology Analyzer BC-720

Maher Matar, Mehmed M. Bakhtaran, Malak M. Keiba
article en

Abstract

Introduction: Diagnosing Leukaemia requires precise identification of atypical whiteblood cells. This research aims to compare the effectiveness of the BC-720 analyzerand manual microscopy in identifying blast and typical cells in both acute and chronicLeukaemia. Manual microscopy and the BC-720 analyzer were used to investigatedifferential white blood cell counts from 68 Leukaemia patients and 18 controls.Sensitivity and error rates for detecting abnormal cells were evaluated. The manualapproach had a recognition loss of 12%, but successfully identified 47.1% of cases. TheBC-720 identified 52.9% of cases, with higher detection rates in chronic patients(41.2%) and control cases (5.9%). In acute cases, the detection loss was 8.0% lower.Both methods showed advantages and limitations. The BC-720 demonstrated higherdetection rates for abnormal cells, particularly in acute Leukaemia, and lowerrecognition losses compared to manual microscopy. It can aid in more accurateLeukaemia classification and management.

Misurata Medical Sciences JournalVol. 5(2)
Misurata University (LY), Libyan Academy (LY)
Openalex Percentile: Top 73%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.