All-Optical Electrochemiluminescence by Light Downconversion at BiVO<sub>4</sub> Photoanodes
Electrochemiluminescence (ECL) is a powerful analytical technique. However, the necessity of an external power supply limits its use for portable sensing devices. Herein, we report a new sensing scheme based on an all-optical ECL (AO-ECL), which addresses this issue by emitting light without external electrical devices but through light excitation (λ<sub>exc</sub>). In AO-ECL, the photovoltage generated by the semiconductor simultaneously drives the anodic ECL reaction (producing photons at λ<sub>AO-ECL</sub>) and a cathodic charge transfer. While this approach significantly reduces the complexity of ECL instrumentation, current materials for such systems often suffer from relatively complex fabrication methods and all existing AO-ECL systems are upconversion systems (e.g., λ<sub>exc</sub> > λ<sub>AO-ECL</sub>). Here, we report for the first time an AO-ECL downconversion process (e.g., λ<sub>exc</sub> < λ<sub>AO-ECL</sub>) based on a bismuth vanadate (BiVO<sub>4</sub>) electrode with the model luminol-H<sub>2</sub>O<sub>2</sub> system. Because BiVO<sub>4</sub> has a wide absorption below 500 nm, the ECL emission spectrum further red-shifts to 510 nm. The strong responsiveness toward H<sub>2</sub>O<sub>2</sub> of the BiVO<sub>4</sub> AO-ECL system enables a significant shift on ECL onset potential from +0.3 V to -0.3 V (vs Ag/AgCl). A nearly 2.6-fold enhancement in ECL intensity was achieved at 0.4 V and the distinct ECL signal is observed even without applied bias. Moreover, the platform enabled cadmium ion (Cd<sup>2+</sup>) detection, with the AO-ECL intensity rising 2.2-fold. The simplicity of BiVO<sub>4</sub> electrode fabrication combined with its cost-effectiveness positions this downconversion AO-ECL system as a potential candidate for the development of portable bioanalytical sensors and wireless bioimaging applications.
Authors
- Xiaodan Gou
- Nešo Šojić (ORCID: https://orcid.org/0000-0001-5144-1015)
- Gabriel Loget (ORCID: https://orcid.org/0000-0003-4809-5013)
- Jun‐Jie Zhu (ORCID: https://orcid.org/0000-0002-8201-1285)
- Changlin Zhou (ORCID: https://orcid.org/0000-0001-7018-0754)
Institutions
- Centre National de la Recherche Scientifique (FR)
- Institut des Sciences Moléculaires (FR)
- State Key Laboratory of Chemical Engineering (CN)
- Institut Polytechnique de Bordeaux (FR)
- Nanjing University (CN)
Publication Details
- Journal
- Analytical Chemistry
- Published
- 2025-10-03
- DOI
- https://doi.org/10.1021/acs.analchem.5c03936
- Citations
- 2
- Primary Topic
- Advanced biosensing and bioanalysis techniques
- Type
- article
- Field-Weighted Citation Impact
- 1.61
Funders
- Centre National de la Recherche Scientifique
- Nanjing University