All-Optical Electrochemiluminescence by Light Downconversion at BiVO<sub>4</sub> Photoanodes

Electrochemiluminescence (ECL) is a powerful analytical technique. However, the necessity of an external power supply limits its use for portable sensing devices. Herein, we report a new sensing scheme based on an all-optical ECL (AO-ECL), which addresses this issue by emitting light without external electrical devices but through light excitation (λ<sub>exc</sub>). In AO-ECL, the photovoltage generated by the semiconductor simultaneously drives the anodic ECL reaction (producing photons at λ<sub>AO-ECL</sub>) and a cathodic charge transfer. While this approach significantly reduces the complexity of ECL instrumentation, current materials for such systems often suffer from relatively complex fabrication methods and all existing AO-ECL systems are upconversion systems (e.g., λ<sub>exc</sub> > λ<sub>AO-ECL</sub>). Here, we report for the first time an AO-ECL downconversion process (e.g., λ<sub>exc</sub> < λ<sub>AO-ECL</sub>) based on a bismuth vanadate (BiVO<sub>4</sub>) electrode with the model luminol-H<sub>2</sub>O<sub>2</sub> system. Because BiVO<sub>4</sub> has a wide absorption below 500 nm, the ECL emission spectrum further red-shifts to 510 nm. The strong responsiveness toward H<sub>2</sub>O<sub>2</sub> of the BiVO<sub>4</sub> AO-ECL system enables a significant shift on ECL onset potential from +0.3 V to -0.3 V (vs Ag/AgCl). A nearly 2.6-fold enhancement in ECL intensity was achieved at 0.4 V and the distinct ECL signal is observed even without applied bias. Moreover, the platform enabled cadmium ion (Cd<sup>2+</sup>) detection, with the AO-ECL intensity rising 2.2-fold. The simplicity of BiVO<sub>4</sub> electrode fabrication combined with its cost-effectiveness positions this downconversion AO-ECL system as a potential candidate for the development of portable bioanalytical sensors and wireless bioimaging applications.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-10-03
DOI
https://doi.org/10.1021/acs.analchem.5c03936
Citations
2
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
1.61

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

All-Optical Electrochemiluminescence by Light Downconversion at BiVO4 Photoanodes

Xiaodan Gou, Nešo Šojić, Gabriel Loget, Jun‐Jie Zhu et al.
2 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
1.61
article

All-Optical Electrochemiluminescence by Light Downconversion at BiVO4 Photoanodes

Xiaodan Gou, Nešo Šojić, Gabriel Loget, Jun‐Jie Zhu, Changlin Zhou
article en
2 citations

Abstract

Electrochemiluminescence (ECL) is a powerful analytical technique. However, the necessity of an external power supply limits its use for portable sensing devices. Herein, we report a new sensing scheme based on an all-optical ECL (AO-ECL), which addresses this issue by emitting light without external electrical devices but through light excitation (λ<sub>exc</sub>). In AO-ECL, the photovoltage generated by the semiconductor simultaneously drives the anodic ECL reaction (producing photons at λ<sub>AO-ECL</sub>) and a cathodic charge transfer. While this approach significantly reduces the complexity of ECL instrumentation, current materials for such systems often suffer from relatively complex fabrication methods and all existing AO-ECL systems are upconversion systems (e.g., λ<sub>exc</sub> > λ<sub>AO-ECL</sub>). Here, we report for the first time an AO-ECL downconversion process (e.g., λ<sub>exc</sub> < λ<sub>AO-ECL</sub>) based on a bismuth vanadate (BiVO<sub>4</sub>) electrode with the model luminol-H<sub>2</sub>O<sub>2</sub> system. Because BiVO<sub>4</sub> has a wide absorption below 500 nm, the ECL emission spectrum further red-shifts to 510 nm. The strong responsiveness toward H<sub>2</sub>O<sub>2</sub> of the BiVO<sub>4</sub> AO-ECL system enables a significant shift on ECL onset potential from +0.3 V to -0.3 V (vs Ag/AgCl). A nearly 2.6-fold enhancement in ECL intensity was achieved at 0.4 V and the distinct ECL signal is observed even without applied bias. Moreover, the platform enabled cadmium ion (Cd<sup>2+</sup>) detection, with the AO-ECL intensity rising 2.2-fold. The simplicity of BiVO<sub>4</sub> electrode fabrication combined with its cost-effectiveness positions this downconversion AO-ECL system as a potential candidate for the development of portable bioanalytical sensors and wireless bioimaging applications.

Analytical ChemistryVol. 97(40)
Centre National de la Recherche Scientifique (FR), Institut des Sciences Moléculaires (FR), State Key Laboratory of Chemical Engineering (CN), Institut Polytechnique de Bordeaux (FR), Nanjing University (CN)
Centre National de la Recherche Scientifique, Nanjing University
Openalex Percentile: Top 14%
Advanced biosensing and bioanalysis techniques
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.