Numerical Study on Moment Redistribution in Continuous Concrete Beams Reinforced with FRP Bars

In harsh environments, steel rebars in concrete corrode; therefore, fiber-reinforced polymer (FRP) bars should be considered due to their non-corrosive nature. Moment distribution in continuous FRP-reinforced concrete beams is prohibited by the design code due to the insufficient ductility of FRP bars. However, studies have shown that FRP-reinforced concrete continuous beams exhibit considerable redistribution of moment. In this study, a nonlinear finite element model of a continuous concrete beam reinforced with basalt FRP bars is developed to numerically investigate the effect of reinforcement configuration on the redistribution of moment. The models exhibit a considerable level of moment redistribution at the internal support (hogging zone) and midspan (sagging zone). When the amount of tensile reinforcement in the sagging zone increases compared to the hogging zone, the moment redistribution at the internal support (hogging zone) increases significantly. Therefore, it is not justified to completely overlook the redistribution of moment in the design of FRP RC continuous beams.

Authors

Institutions

Publication Details

Journal
Fusion Journal of Engineering and Sciences
Published
2025-10-04
DOI
https://doi.org/10.64615/fjes.1.specialissue.2025.47
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Study on Moment Redistribution in Continuous Concrete Beams Reinforced with FRP Bars

Muhammad Owais, Abdul Jabbar Sangi, Rajesh Kumar, Muhammad Saad Ifrahim
Fusion Journal of Engineering and Sciences
Structural Behavior of Reinforced Concrete
article

Numerical Study on Moment Redistribution in Continuous Concrete Beams Reinforced with FRP Bars

Muhammad Owais, Abdul Jabbar Sangi, Rajesh Kumar, Muhammad Saad Ifrahim
article en

Abstract

In harsh environments, steel rebars in concrete corrode; therefore, fiber-reinforced polymer (FRP) bars should be considered due to their non-corrosive nature. Moment distribution in continuous FRP-reinforced concrete beams is prohibited by the design code due to the insufficient ductility of FRP bars. However, studies have shown that FRP-reinforced concrete continuous beams exhibit considerable redistribution of moment. In this study, a nonlinear finite element model of a continuous concrete beam reinforced with basalt FRP bars is developed to numerically investigate the effect of reinforcement configuration on the redistribution of moment. The models exhibit a considerable level of moment redistribution at the internal support (hogging zone) and midspan (sagging zone). When the amount of tensile reinforcement in the sagging zone increases compared to the hogging zone, the moment redistribution at the internal support (hogging zone) increases significantly. Therefore, it is not justified to completely overlook the redistribution of moment in the design of FRP RC continuous beams.

Fusion Journal of Engineering and Sciences
NED University of Engineering and Technology (PK)
University of Engineering and Technology, Lahore, NED University of Engineering and Technology
Openalex Percentile: Top 70%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.