Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater

This study investigates the elimination of chemical oxygen demand (COD) from an Iraqi petroleum refinery effluent through a combined electro-Fenton and adsorption process (EF+AC). Response surface methodology (RSM) with a Box-Behnken design (BBD) was employed to investigate the effects of FeSO<sub>4</sub> concentration, current density, and electrolysis time on the reduction of COD using the EF technique. According to the results of the analysis of variance (ANOVA) for the EF technique, FeSO<sub>4</sub> concentrations, with a contribution of 40.06%, and current density, with a contribution of 46.35%, exert a considerable influence. The optimum conditions for COD elimination rate (99.06%) and energy consumption (9.805 kWh/kg COD) were achieved using an electrolysis time of 85.12 min, a current density of 25 mA/cm<sup>2</sup>, and a concentration of 1.335 mM FeSO<sub>4</sub>. For the EF+AC process, a central composite design (CCD) was used to determine the influence of the packing level of activated carbon (AC) and the time on the reduction of COD at a constant current density of 5 mA/cm<sup>2</sup> and FeSO<sub>4</sub> concentration of 0.2 mM. The packing level of AC significantly influenced the elimination of COD, with time being the subsequent factor. The results showed that the optimal conditions led to a 98.77% removal of COD, requiring 0.91 kWh/kg COD. This efficiency and energy consumption were attained by using 92% packed AC and allowing the process to run for 85 min. EF+AC was found to have lower energy consumption and a smaller quantity of ferrous sulfate compared to EF. Notably, the current system offers a promising vision by combining the benefits of adsorption and electro-Fenton for wastewater remediation.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2025-10-01
DOI
https://doi.org/10.1002/wer.70185
Citations
1
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.82
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater

Ali N. Kassob, Ali H. Abbar, Zainab Talib Al-Sharify, Zaid H. Jabbar et al.
1 citations
Water Environment Research
Advanced oxidation water treatment
0.82
article

Combining Electro Fenton With Adsorption Processes for Treatment of Petroleum Refinery Wastewater

Ali N. Kassob, Ali H. Abbar, Zainab Talib Al-Sharify, Zaid H. Jabbar, Abdullah Y. Ghjeer
article en
1 citations

Abstract

This study investigates the elimination of chemical oxygen demand (COD) from an Iraqi petroleum refinery effluent through a combined electro-Fenton and adsorption process (EF+AC). Response surface methodology (RSM) with a Box-Behnken design (BBD) was employed to investigate the effects of FeSO<sub>4</sub> concentration, current density, and electrolysis time on the reduction of COD using the EF technique. According to the results of the analysis of variance (ANOVA) for the EF technique, FeSO<sub>4</sub> concentrations, with a contribution of 40.06%, and current density, with a contribution of 46.35%, exert a considerable influence. The optimum conditions for COD elimination rate (99.06%) and energy consumption (9.805 kWh/kg COD) were achieved using an electrolysis time of 85.12 min, a current density of 25 mA/cm<sup>2</sup>, and a concentration of 1.335 mM FeSO<sub>4</sub>. For the EF+AC process, a central composite design (CCD) was used to determine the influence of the packing level of activated carbon (AC) and the time on the reduction of COD at a constant current density of 5 mA/cm<sup>2</sup> and FeSO<sub>4</sub> concentration of 0.2 mM. The packing level of AC significantly influenced the elimination of COD, with time being the subsequent factor. The results showed that the optimal conditions led to a 98.77% removal of COD, requiring 0.91 kWh/kg COD. This efficiency and energy consumption were attained by using 92% packed AC and allowing the process to run for 85 min. EF+AC was found to have lower energy consumption and a smaller quantity of ferrous sulfate compared to EF. Notably, the current system offers a promising vision by combining the benefits of adsorption and electro-Fenton for wastewater remediation.

Water Environment ResearchVol. 97(10)
University of Baghdad (IQ), Mustansiriyah University (IQ), Alsalam University College (IQ), University of Al-Qadisiyah (IQ), University of Birmingham (GB)
Openalex Percentile: Top 22%
Advanced oxidation water treatment
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.