Microplastic and Nanoplastic Analysis: From Pyrolysis Gas Chromatography‐Mass Spectrometry to Pyrolysis Two‐dimensional Gas Chromatography‐Mass Spectrometry—A Critical Review

The growing environmental and health concerns regarding micro- and nanoplastics (MNPs) have prompted the development of advanced analytical methods for accurate characterization and quantification. Pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) enables polymer identification by their thermal destruction into characteristic fragments. However, the small particle size and interferences originating from complex sample matrices complicate its analysis. Therefore, the integration of comprehensive two-dimensional GC (GC×GC) would improve separation efficiency and sensitivity and provide a detailed composition of environmental and biological samples. This review documents (i) the evolution of Py-GC-MS and (ii) the potential to resolve overlapping compounds, improving quantification accuracy, and detecting minor plastic compounds and degradation byproducts by comprehensive GC×GC-MS as a crucial approach to measure MNPs. Despite the documented advancements, key challenges persist. The lack of standardized protocols for sample preparation and calibration, impeding the comparability of studies, is of prime concern. The massive presence of (in)organic interferences even further accentuates the absence of internal standards in terms of quantification. Therefore, to improve analytical reliability, future research should focus on developing standardized methodologies, improving detection sensitivity for NPs, and incorporating complementary approaches. Additionally, coupling GC×GC with time-of-flight MS further strengthens its capability to provide higher analytical resolution power and better chemical description of pyrolyzates. This review highlights the crucial role of advanced Py and chromatography-based techniques in supporting the analytical description of the extent of plastic pollution and in supporting evidence-based policymaking and successful mitigation efforts to protect ecosystems and public health.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-10-01
DOI
https://doi.org/10.1002/jssc.70287
Citations
5
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
2.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microplastic and Nanoplastic Analysis: From Pyrolysis Gas Chromatography‐Mass Spectrometry to Pyrolysis Two‐dimensional Gas Chromatography‐Mass Spectrometry—A Critical Review

Géraldine Dumont, Pierre‐Hugues Stefanuto, Anaïs Rodrigues, Milica Velimirović et al.
5 citations
Journal of Separation Science
Microplastics and Plastic Pollution
2.52
article

Microplastic and Nanoplastic Analysis: From Pyrolysis Gas Chromatography‐Mass Spectrometry to Pyrolysis Two‐dimensional Gas Chromatography‐Mass Spectrometry—A Critical Review

Géraldine Dumont, Pierre‐Hugues Stefanuto, Anaïs Rodrigues, Milica Velimirović, Siebe Lievens, Jean‐François Focant, Jan Jordens
article en
5 citations

Abstract

The growing environmental and health concerns regarding micro- and nanoplastics (MNPs) have prompted the development of advanced analytical methods for accurate characterization and quantification. Pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) enables polymer identification by their thermal destruction into characteristic fragments. However, the small particle size and interferences originating from complex sample matrices complicate its analysis. Therefore, the integration of comprehensive two-dimensional GC (GC×GC) would improve separation efficiency and sensitivity and provide a detailed composition of environmental and biological samples. This review documents (i) the evolution of Py-GC-MS and (ii) the potential to resolve overlapping compounds, improving quantification accuracy, and detecting minor plastic compounds and degradation byproducts by comprehensive GC×GC-MS as a crucial approach to measure MNPs. Despite the documented advancements, key challenges persist. The lack of standardized protocols for sample preparation and calibration, impeding the comparability of studies, is of prime concern. The massive presence of (in)organic interferences even further accentuates the absence of internal standards in terms of quantification. Therefore, to improve analytical reliability, future research should focus on developing standardized methodologies, improving detection sensitivity for NPs, and incorporating complementary approaches. Additionally, coupling GC×GC with time-of-flight MS further strengthens its capability to provide higher analytical resolution power and better chemical description of pyrolyzates. This review highlights the crucial role of advanced Py and chromatography-based techniques in supporting the analytical description of the extent of plastic pollution and in supporting evidence-based policymaking and successful mitigation efforts to protect ecosystems and public health.

Journal of Separation ScienceVol. 48(10)
University of Liège (BE), Flemish Institute for Technological Research (BE)
Openalex Percentile: Top 10%
Microplastics and Plastic Pollution
2.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.