Heat Loss on Stone and Plastic Media Trickling Filters

ABSTRACT Temperature surveys were conducted on three conventional low‐rate stone media trickling filter plants, typical of those used in the United Kingdom, and one set of shallow (1.8 m) structured plastic media filters was surveyed. Filter feed, effluent and ambient air temperatures were continuously monitored for 6–13 months and covered winter conditions in all cases. A strong link was observed between measured heat loss from the effluent and the convective airflow driver, defined as the temperature differential between the wastewater feed and ambient air. The relationships were quantified for stone and plastic media to produce models that describe the observed heat loss in terms of this temperature differential, hydraulic load in the case of the plastic media model and media depth. Plastic media was found to have a higher cooling capacity and lacks the thermal inertia associated with traditional stone media units. Results and potential mechanisms are discussed.

Authors

Institutions

Publication Details

Journal
Water and Environment Journal
Published
2025-10-04
DOI
https://doi.org/10.1111/wej.70022
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Loss on Stone and Plastic Media Trickling Filters

Pete Pearce
Water and Environment Journal
Surface Modification and Superhydrophobicity
article

Heat Loss on Stone and Plastic Media Trickling Filters

Pete Pearce
article en

Abstract

ABSTRACT Temperature surveys were conducted on three conventional low‐rate stone media trickling filter plants, typical of those used in the United Kingdom, and one set of shallow (1.8 m) structured plastic media filters was surveyed. Filter feed, effluent and ambient air temperatures were continuously monitored for 6–13 months and covered winter conditions in all cases. A strong link was observed between measured heat loss from the effluent and the convective airflow driver, defined as the temperature differential between the wastewater feed and ambient air. The relationships were quantified for stone and plastic media to produce models that describe the observed heat loss in terms of this temperature differential, hydraulic load in the case of the plastic media model and media depth. Plastic media was found to have a higher cooling capacity and lacks the thermal inertia associated with traditional stone media units. Results and potential mechanisms are discussed.

Water and Environment Journal
Cornwall Council (GB)
Openalex Percentile: Top 74%
Surface Modification and Superhydrophobicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.