Wettability, UV Absorption, and SEM Investigation of PMMA after Immersion in Ozone Water

Purpose: Denture stomatitis, poor oral health, and angular cheilitis can all result from bacterial and fungal colonization. As a result, denture cleaners have been suggested to preserve the longevity of partially removable dentures and the health of the oral mucosa. The purpose of the present study was to investigate the impact of ozone water on Polymethyl Methacrylate (PMMA) by studying wettability, Ultraviolet (UV) absorption, and surface topography following soaking for 10 and 20 minutes at a 2 mg/l concentration. Materials and Methods: A sixty-disc-shaped sample of polymethacrylate material (Ivoclar Vivadent) was fabricated for the wettability and UV absorption tests, and three bar-shaped samples of polymethacrylate material (Ivoclar Vivadent) were fabricated for the surface topography. Three groups were created: the first was the control group (immersion of samples in distal water). Second group (immersion of samples in 2 mg/l of ozone water solution for 10 min), and third group (immersion of samples in 2 mg/l of ozone water solution for 20 min). The contact angle (a wettability parameter) on the surfaces of the samples was measured after each storage period. The UV absorption test was assessed using a spectrophotometer; ANOVA was used to perform statistical analysis on the data at level 0.0.5; and surface topography was evaluated using Scanning Electron Microscopy (SEM). Results: Based on the findings of this research, there was no statistically significant difference between the experimental and control groups when testing wettability and UV absorption. There is no change in surface topography when assessed by SEM. Conclusion: This research concluded that the samples prepared from PMMA material can be safely soaked in an ozone water solution without compromising their properties.

Authors

Institutions

Publication Details

Journal
Frontiers in biomedical technologies
Published
2025-10-04
DOI
https://doi.org/10.18502/fbt.v12i4.19825
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wettability, UV Absorption, and SEM Investigation of PMMA after Immersion in Ozone Water

Shawq Azmi Tawfeeq, Aseel Mohammed Al-Khafaji
Frontiers in biomedical technologies
Surface Modification and Superhydrophobicity
article

Wettability, UV Absorption, and SEM Investigation of PMMA after Immersion in Ozone Water

Shawq Azmi Tawfeeq, Aseel Mohammed Al-Khafaji
article en

Abstract

Purpose: Denture stomatitis, poor oral health, and angular cheilitis can all result from bacterial and fungal colonization. As a result, denture cleaners have been suggested to preserve the longevity of partially removable dentures and the health of the oral mucosa. The purpose of the present study was to investigate the impact of ozone water on Polymethyl Methacrylate (PMMA) by studying wettability, Ultraviolet (UV) absorption, and surface topography following soaking for 10 and 20 minutes at a 2 mg/l concentration. Materials and Methods: A sixty-disc-shaped sample of polymethacrylate material (Ivoclar Vivadent) was fabricated for the wettability and UV absorption tests, and three bar-shaped samples of polymethacrylate material (Ivoclar Vivadent) were fabricated for the surface topography. Three groups were created: the first was the control group (immersion of samples in distal water). Second group (immersion of samples in 2 mg/l of ozone water solution for 10 min), and third group (immersion of samples in 2 mg/l of ozone water solution for 20 min). The contact angle (a wettability parameter) on the surfaces of the samples was measured after each storage period. The UV absorption test was assessed using a spectrophotometer; ANOVA was used to perform statistical analysis on the data at level 0.0.5; and surface topography was evaluated using Scanning Electron Microscopy (SEM). Results: Based on the findings of this research, there was no statistically significant difference between the experimental and control groups when testing wettability and UV absorption. There is no change in surface topography when assessed by SEM. Conclusion: This research concluded that the samples prepared from PMMA material can be safely soaked in an ozone water solution without compromising their properties.

Frontiers in biomedical technologies
University of Baghdad (IQ)
Openalex Percentile: Top 74%
Surface Modification and Superhydrophobicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.