Waste-to-sensor: Repurposing spent Li-ion battery graphite into reduced graphene oxide for electrochemical detection of ascorbic acid

Spent lithium-ion batteries (S-LIBs) are typically discarded in landfills after their lifecycle ends, despite containing valuable materials like graphite. While much research focuses on extracting precious metals from the cathode, this study explores the recycling, recovery, and reuse of spent graphite, converting it into reduced graphene oxide (rGO) for electrochemical sensing. The rGO material demonstrated excellent sensitivity to ascorbic acid (AA) in a concentration range of 1 mM to 100 mM at pH 7.6, offering a cost-effective solution for AA detection. The recovered graphite (RG) from S-LIBs and commercial graphite (CG) was first converted into graphene oxide (R-GO, C-GO) and then reduced (R-rGO, C-rGO). This material underwent extensive structural characterization using techniques such as powder X-ray diffraction (PXRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), Brunauer-Emmett-Teller (BET) analysis, field-emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HR-TEM). Electrochemical performance was evaluated through cyclic voltammetry (CV), differential pulse voltammetry (DPV). This study underscores the "waste-to-wealth" concept and supports circular economy principles by transforming electronic waste into a valuable resource. The LOD and LOQ for both the material R-rGO and C-rGO were calculated as 3.055 mM, 10.18 mM, and 3.41 mM, 11.36 mM, respectively. The rGO-based sensor not only promotes sustainable recycling but also offers a low-cost, high-performance solution for ascorbic acid detection, with potential applications in food quality monitoring, medical diagnostics, and the cosmetic industry.

Authors

Institutions

Publication Details

Journal
Resources Conservation and Recycling
Published
2025-10-04
DOI
https://doi.org/10.1016/j.resconrec.2025.108610
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Waste-to-sensor: Repurposing spent Li-ion battery graphite into reduced graphene oxide for electrochemical detection of ascorbic acid

B. P. Shivamurthy, Girish Praveen Nayaka, Purnima Rawat, V. J. PATIL
1 citations
Resources Conservation and Recycling
Electrochemical sensors and biosensors
0.73
article

Waste-to-sensor: Repurposing spent Li-ion battery graphite into reduced graphene oxide for electrochemical detection of ascorbic acid

B. P. Shivamurthy, Girish Praveen Nayaka, Purnima Rawat, V. J. PATIL
article en
1 citations

Abstract

Spent lithium-ion batteries (S-LIBs) are typically discarded in landfills after their lifecycle ends, despite containing valuable materials like graphite. While much research focuses on extracting precious metals from the cathode, this study explores the recycling, recovery, and reuse of spent graphite, converting it into reduced graphene oxide (rGO) for electrochemical sensing. The rGO material demonstrated excellent sensitivity to ascorbic acid (AA) in a concentration range of 1 mM to 100 mM at pH 7.6, offering a cost-effective solution for AA detection. The recovered graphite (RG) from S-LIBs and commercial graphite (CG) was first converted into graphene oxide (R-GO, C-GO) and then reduced (R-rGO, C-rGO). This material underwent extensive structural characterization using techniques such as powder X-ray diffraction (PXRD), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), Brunauer-Emmett-Teller (BET) analysis, field-emission scanning electron microscopy (FE-SEM), and high-resolution transmission electron microscopy (HR-TEM). Electrochemical performance was evaluated through cyclic voltammetry (CV), differential pulse voltammetry (DPV). This study underscores the "waste-to-wealth" concept and supports circular economy principles by transforming electronic waste into a valuable resource. The LOD and LOQ for both the material R-rGO and C-rGO were calculated as 3.055 mM, 10.18 mM, and 3.41 mM, 11.36 mM, respectively. The rGO-based sensor not only promotes sustainable recycling but also offers a low-cost, high-performance solution for ascorbic acid detection, with potential applications in food quality monitoring, medical diagnostics, and the cosmetic industry.

Resources Conservation and RecyclingVol. 225
National Chemical Laboratory (IN), Academy of Scientific and Innovative Research (IN)
Openalex Percentile: Top 23%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.