Design of an adaptive identification method for faulty operating states of power system relay protection devices

• Proposes adaptive ResNet50-based method for relay protection fault identification in complex grids. • Integrates residual connections with probabilistic learning for enhanced fault feature extraction. • Leverages same-source data comparison to improve state recognition accuracy across system complexities. • Validates zero-sequence overcurrent adaptation for multi-scale fault pattern characterization. • Achieves 92.7% recognition accuracy with 15% faster convergence than conventional CNN architectures. To address the high complexity and diversity of faults in relay protection devices, as well as the challenges in fault feature extraction that affect fault identification accuracy, an adaptive recognition method is proposed for identifying the faulty operation states of power system relay protection devices. The zero-sequence inverse-time overcurrent protection method is utilized to enable adaptive adjustments within these devices. A same-source data comparison approach is adopted to collect faulty operation state data from power system relay protection devices, which serves as the input for the ResNet50 network. This network, consisting of 50 convolutional layers, processes complex fault features from the input data and captures extensive fault feature information through its powerful feature representation capability. The network layers are interconnected via residual connections, and adaptive probabilistic learning is applied during network training. The fault features extracted by the relay protection device are mapped to a label space through a fully connected layer, and the adaptive recognition results for the faulty operation states are generated using a softmax function. The experimental results demonstrate that the proposed method accurately identifies faulty operation states in relay protection devices and exhibits adaptability to power systems of varying complexities.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-10-04
DOI
https://doi.org/10.1016/j.rineng.2025.107568
Citations
1
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of an adaptive identification method for faulty operating states of power system relay protection devices

Weiming Luo, J. Wang, Zhijun Guo, Jionghui Wei
1 citations
Results in Engineering
Power Systems Fault Detection
1.21
article

Design of an adaptive identification method for faulty operating states of power system relay protection devices

Weiming Luo, J. Wang, Zhijun Guo, Jionghui Wei
article en
1 citations

Abstract

• Proposes adaptive ResNet50-based method for relay protection fault identification in complex grids. • Integrates residual connections with probabilistic learning for enhanced fault feature extraction. • Leverages same-source data comparison to improve state recognition accuracy across system complexities. • Validates zero-sequence overcurrent adaptation for multi-scale fault pattern characterization. • Achieves 92.7% recognition accuracy with 15% faster convergence than conventional CNN architectures. To address the high complexity and diversity of faults in relay protection devices, as well as the challenges in fault feature extraction that affect fault identification accuracy, an adaptive recognition method is proposed for identifying the faulty operation states of power system relay protection devices. The zero-sequence inverse-time overcurrent protection method is utilized to enable adaptive adjustments within these devices. A same-source data comparison approach is adopted to collect faulty operation state data from power system relay protection devices, which serves as the input for the ResNet50 network. This network, consisting of 50 convolutional layers, processes complex fault features from the input data and captures extensive fault feature information through its powerful feature representation capability. The network layers are interconnected via residual connections, and adaptive probabilistic learning is applied during network training. The fault features extracted by the relay protection device are mapped to a label space through a fully connected layer, and the adaptive recognition results for the faulty operation states are generated using a softmax function. The experimental results demonstrate that the proposed method accurately identifies faulty operation states in relay protection devices and exhibits adaptability to power systems of varying complexities.

Results in EngineeringVol. 28
China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Openalex Percentile: Top 16%
Power Systems Fault Detection
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.