Minimally invasive fixation of a peri-implant femoral neck fracture without nail removal: A case report

We present the case of a 53-year-old female patient with a peri-implant transcervical femoral fracture associated with an intramedullary nail (IMN) implanted over 10 years ago following a low-energy fall from standing height. The preexisting implant constrained traditional surgical options due to the risks associated with nail removal, such as iatrogenic fractures and soft tissue damage. Closed reduction assisted by a traction table was performed, followed by internal fixation with cannulated screws in an inverted triangular configuration, preserving the preexisting implant and avoiding surgical complications. Clinical and functional follow-up demonstrated a satisfactory recovery. At 6 weeks, the Harris Hip Score (HHS) and Oxford Hip Score (OHS) indicated moderate recovery, with progressive improvement reaching excellent scores at 1 year (HHS: 96, OHS: 46). This case highlights the feasibility of cannulated screws as a minimally invasive and effective strategy for peri-implant transcervical fractures, maximizing patient benefits while minimizing surgical risks.

Authors

Institutions

Publication Details

Journal
Trauma Case Reports
Published
2025-10-04
DOI
https://doi.org/10.1016/j.tcr.2025.101252
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimally invasive fixation of a peri-implant femoral neck fracture without nail removal: A case report

Carlos Peñaherrera, Paul Vaca Perez, Alejandro Barros Castro, Francisco Endara et al.
Trauma Case Reports
Hip and Femur Fractures
article

Minimally invasive fixation of a peri-implant femoral neck fracture without nail removal: A case report

Carlos Peñaherrera, Paul Vaca Perez, Alejandro Barros Castro, Francisco Endara, Edgar Barros, Carlos Ballesteros, Eduardo Noboa, Diego Michilena
article en

Abstract

We present the case of a 53-year-old female patient with a peri-implant transcervical femoral fracture associated with an intramedullary nail (IMN) implanted over 10 years ago following a low-energy fall from standing height. The preexisting implant constrained traditional surgical options due to the risks associated with nail removal, such as iatrogenic fractures and soft tissue damage. Closed reduction assisted by a traction table was performed, followed by internal fixation with cannulated screws in an inverted triangular configuration, preserving the preexisting implant and avoiding surgical complications. Clinical and functional follow-up demonstrated a satisfactory recovery. At 6 weeks, the Harris Hip Score (HHS) and Oxford Hip Score (OHS) indicated moderate recovery, with progressive improvement reaching excellent scores at 1 year (HHS: 96, OHS: 46). This case highlights the feasibility of cannulated screws as a minimally invasive and effective strategy for peri-implant transcervical fractures, maximizing patient benefits while minimizing surgical risks.

Trauma Case ReportsVol. 60
Instituto Nacional de Rehabilitación (MX), Universidad Internacional del Ecuador (EC), Hospital Metropolitano (EC), Hospital Vozandes (EC)
Openalex Percentile: Top 56%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.