Optimization of three-layer staggered liquid cooling system for high-rate charging of large cylindrical battery module in electric vehicles

• A TSLP based thermal management system for large cylindrical batteries was proposed. • The optimal thermal management structure was determined through single-factor analysis. • The influence of different factors was analyzed using BBD response surface optimization. • The BBD optimization results were validated through CFD simulations and experiments. Efficient thermal management is essential for ensuring the safety and reliability of large cylindrical lithium-ion battery modules under ultra-fast charging. This study proposes a three-layer staggered liquid-cooled pipe (TSLP) design for a 37-cell (32700) module and evaluates its performance through combined computational fluid dynamics (CFD) simulation, experimental validation, and Box-Behnken design (BBD) optimization. Parametric analyses reveal that a staggered counter-flow layout with a middle-layer pipe height of 34 mm and wall thickness of 0.6 mm achieves favorable temperature control, with a peak module temperature of 36.17 °C and a maximum inter-cell temperature difference of 2.43 °C. A BBD response surface methodology was employed to optimize operating conditions, including inlet flow rate, ambient temperature, and coolant precooling rate. The optimal solutions at ambient temperatures of 35/40/45 °C correspond to inlet velocities of approximately 0.044/0.047/0.049 m/s and precooling rates of 3.6–3.9 °C/min. Validation shows high consistency between experimental data, CFD simulations, and BBD predictions, with deviations below 0.4 °C. These results demonstrate that the TSLP system offers improved cooling uniformity and scalability for large-format cylindrical cells, providing practical guidance for high-power battery thermal management in electric vehicles.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-10-04
DOI
https://doi.org/10.1016/j.applthermaleng.2025.128585
Citations
2
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
1.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of three-layer staggered liquid cooling system for high-rate charging of large cylindrical battery module in electric vehicles

Jianbang Zeng, Feifei Liu, Qilong Yang, Yongkuan Sun et al.
2 citations
Applied Thermal Engineering
Advanced Battery Technologies Research
1.37
article

Optimization of three-layer staggered liquid cooling system for high-rate charging of large cylindrical battery module in electric vehicles

Jianbang Zeng, Feifei Liu, Qilong Yang, Yongkuan Sun, Xianfu Cheng, Wu Qin
article en
2 citations

Abstract

• A TSLP based thermal management system for large cylindrical batteries was proposed. • The optimal thermal management structure was determined through single-factor analysis. • The influence of different factors was analyzed using BBD response surface optimization. • The BBD optimization results were validated through CFD simulations and experiments. Efficient thermal management is essential for ensuring the safety and reliability of large cylindrical lithium-ion battery modules under ultra-fast charging. This study proposes a three-layer staggered liquid-cooled pipe (TSLP) design for a 37-cell (32700) module and evaluates its performance through combined computational fluid dynamics (CFD) simulation, experimental validation, and Box-Behnken design (BBD) optimization. Parametric analyses reveal that a staggered counter-flow layout with a middle-layer pipe height of 34 mm and wall thickness of 0.6 mm achieves favorable temperature control, with a peak module temperature of 36.17 °C and a maximum inter-cell temperature difference of 2.43 °C. A BBD response surface methodology was employed to optimize operating conditions, including inlet flow rate, ambient temperature, and coolant precooling rate. The optimal solutions at ambient temperatures of 35/40/45 °C correspond to inlet velocities of approximately 0.044/0.047/0.049 m/s and precooling rates of 3.6–3.9 °C/min. Validation shows high consistency between experimental data, CFD simulations, and BBD predictions, with deviations below 0.4 °C. These results demonstrate that the TSLP system offers improved cooling uniformity and scalability for large-format cylindrical cells, providing practical guidance for high-power battery thermal management in electric vehicles.

Applied Thermal EngineeringVol. 280
Beijing Institute of Technology (CN), East China Jiaotong University (CN), Zhuhai Institute of Advanced Technology (CN)
Openalex Percentile: Top 17%
Advanced Battery Technologies Research
1.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.