Validation of markerless motion capture for spatiotemporal gait measures in people with Parkinson’s disease

Spatiotemporal gait measures are increasingly important for the characterization of gait impairments in people with Parkinson's disease (PD). Hence new assessment methods, like markerless motion capture using Theia3D, are of rising interest. This study aims to validate markerless motion capture in people with PD to retrieve spatiotemporal gait measures during overground and treadmill walking. Overground- and treadmill walking at comfortable speed were assessed in 30 individuals with PD. Markerbased and markerless motion capture were carried out in randomized order with the markerbased method using a model with markers at the heel, the lateral ankle and the toe. The markerless data (Theia Markerless Inc., Kingston, ON, Canada) was analyzed 1) with the same model as the markerbased data and 2) within the automatic report pipeline. Agreement between the measurements was assessed via mean differences, Pearson correlation coefficients, intraclass correlation coefficients and Bland-Altman methods. The results show good to excellent agreement (ICC > 0.75) between spatiotemporal gait measures of the two measurements for overground walking, except for double support time (ICC < 0.5), when analyzed with our custom algorithm. For treadmill walking all outcomes had excellent agreement (ICC > 0.9). Mean differences were below the minimal clinical differences for gait speed and step length. For the results of the automatic report during overground gait agreement between methods was poor except for gait speed and step length. Overall, the markerless motion capture system used in this study provides valid results for the assessment of spatial and temporal gait variables in people with PD, when using a gait detection algorithm that is suitable for this population.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2025-10-04
DOI
https://doi.org/10.1016/j.jbiomech.2025.113008
Citations
1
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
4.76
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of markerless motion capture for spatiotemporal gait measures in people with Parkinson’s disease

Christian Schlenstedt, Jule Grotherr, Jana Seuthe, Fábio Augusto Barbieri et al.
1 citations
Journal of Biomechanics
Balance, Gait, and Falls Prevention
4.76
article

Validation of markerless motion capture for spatiotemporal gait measures in people with Parkinson’s disease

Christian Schlenstedt, Jule Grotherr, Jana Seuthe, Fábio Augusto Barbieri, Björn Hauptmann
article en
1 citations

Abstract

Spatiotemporal gait measures are increasingly important for the characterization of gait impairments in people with Parkinson's disease (PD). Hence new assessment methods, like markerless motion capture using Theia3D, are of rising interest. This study aims to validate markerless motion capture in people with PD to retrieve spatiotemporal gait measures during overground and treadmill walking. Overground- and treadmill walking at comfortable speed were assessed in 30 individuals with PD. Markerbased and markerless motion capture were carried out in randomized order with the markerbased method using a model with markers at the heel, the lateral ankle and the toe. The markerless data (Theia Markerless Inc., Kingston, ON, Canada) was analyzed 1) with the same model as the markerbased data and 2) within the automatic report pipeline. Agreement between the measurements was assessed via mean differences, Pearson correlation coefficients, intraclass correlation coefficients and Bland-Altman methods. The results show good to excellent agreement (ICC > 0.75) between spatiotemporal gait measures of the two measurements for overground walking, except for double support time (ICC < 0.5), when analyzed with our custom algorithm. For treadmill walking all outcomes had excellent agreement (ICC > 0.9). Mean differences were below the minimal clinical differences for gait speed and step length. For the results of the automatic report during overground gait agreement between methods was poor except for gait speed and step length. Overall, the markerless motion capture system used in this study provides valid results for the assessment of spatial and temporal gait variables in people with PD, when using a gait detection algorithm that is suitable for this population.

Journal of BiomechanicsVol. 193
MSH Medical School Hamburg – University of Applied Sciences and Medical University (DE), Segeberger Kliniken (DE), Universidade Estadual Paulista (Unesp) (BR)
Openalex Percentile: Top 5%
Balance, Gait, and Falls Prevention
4.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.