P07.08.B INTRAOPERATIVE ASSESSMENT OF GLIOMA USING MINIATURIZED EPI-FLUORESCENCE WIDEFIELD MICROSCOPE: A PROSPECTIVE COMPARATIVE STUDY OF EX-VIVO AND IN-VIVO APPLICATIONS

Abstract BACKGROUND This study evaluated the Miniaturized Epi-fluorescence Widefield Microscope (MEW-M) system using the EndoSCell™ device for intraoperative glioma assessment. MATERIAL AND METHODS The MEW-M system used a rapid staining protocol with fluorescein sodium and methylene blue. The study included 70 glioma patients (mean age 55.9 years, 57% male). Ex-vivo evaluation was done on central tumor core specimens, and in-vivo assessment on margin specimens at the tumor-brain interface. This study is registered with Chinese Clinical Trial Registry (ChiCTR2500101224). RESULTS For tumor core specimens, both pathologists and neurosurgeons achieved 100% sensitivity and accuracy. For margin specimens, pathologists had 100% sensitivity, 88.9% specificity, and 96.0% accuracy, while neurosurgeons had 100% sensitivity, 74.1% specificity, and 90.7% accuracy. In WHO grade stratification, both groups showed identical performance for low-grade gliomas (100% sensitivity, 75.0% specificity, 91.3% accuracy), but pathologists had superior specificity and accuracy for high-grade gliomas compared to neurosurgeons. The MEW-M system significantly reduced procedural time compared to frozen section analysis (3.42±1.04 vs 32.93±11.37 minutes). In tumor cavity assessment, MEW-M detected residual tumor in 74.2% of cases. CONCLUSION The study concluded that the MEW-M system is effective for glioma detection, reduces processing time, and provides comparable diagnostic performance to conventional methods, potentially improving surgical decision-making during glioma resection.

Authors

Institutions

Publication Details

Journal
Neuro-Oncology
Published
2025-10-01
DOI
https://doi.org/10.1093/neuonc/noaf193.254
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P07.08.B INTRAOPERATIVE ASSESSMENT OF GLIOMA USING MINIATURIZED EPI-FLUORESCENCE WIDEFIELD MICROSCOPE: A PROSPECTIVE COMPARATIVE STUDY OF EX-VIVO AND IN-VIVO APPLICATIONS

Jian Zhang
Neuro-Oncology
Nanoplatforms for cancer theranostics
article

P07.08.B INTRAOPERATIVE ASSESSMENT OF GLIOMA USING MINIATURIZED EPI-FLUORESCENCE WIDEFIELD MICROSCOPE: A PROSPECTIVE COMPARATIVE STUDY OF EX-VIVO AND IN-VIVO APPLICATIONS

Jian Zhang
article en

Abstract

Abstract BACKGROUND This study evaluated the Miniaturized Epi-fluorescence Widefield Microscope (MEW-M) system using the EndoSCell™ device for intraoperative glioma assessment. MATERIAL AND METHODS The MEW-M system used a rapid staining protocol with fluorescein sodium and methylene blue. The study included 70 glioma patients (mean age 55.9 years, 57% male). Ex-vivo evaluation was done on central tumor core specimens, and in-vivo assessment on margin specimens at the tumor-brain interface. This study is registered with Chinese Clinical Trial Registry (ChiCTR2500101224). RESULTS For tumor core specimens, both pathologists and neurosurgeons achieved 100% sensitivity and accuracy. For margin specimens, pathologists had 100% sensitivity, 88.9% specificity, and 96.0% accuracy, while neurosurgeons had 100% sensitivity, 74.1% specificity, and 90.7% accuracy. In WHO grade stratification, both groups showed identical performance for low-grade gliomas (100% sensitivity, 75.0% specificity, 91.3% accuracy), but pathologists had superior specificity and accuracy for high-grade gliomas compared to neurosurgeons. The MEW-M system significantly reduced procedural time compared to frozen section analysis (3.42±1.04 vs 32.93±11.37 minutes). In tumor cavity assessment, MEW-M detected residual tumor in 74.2% of cases. CONCLUSION The study concluded that the MEW-M system is effective for glioma detection, reduces processing time, and provides comparable diagnostic performance to conventional methods, potentially improving surgical decision-making during glioma resection.

Neuro-OncologyVol. 27(Supplement_3)
Nanjing Medical University (CN)
Openalex Percentile: Top 74%
Nanoplatforms for cancer theranostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

P07.08.B INTRAOPERATIVE ASSESSMENT OF GLIOMA USING MINIATURIZED EPI-FLUORESCENCE WIDEFIELD MICROSCOPE: A PROSPECTIVE COMPARATIVE STUDY OF EX-VIVO AND IN-VIVO APPLICATIONS — Jian Zhang · Neuro-Oncology (2025) | TGRS Research Map | TGRS