Use of Robotics in Colorectal Surgery: An Initial Single-Centre Experience

Background Robotic-assisted surgery is increasingly recognised as a viable alternative to conventional open and laparoscopic techniques in colorectal cancer (CRC) management. This study presents a single-centre initial experience with the Versius® robotic system for colorectal resections between April 2023 and March 2024. Methodology A retrospective cohort study was conducted at a University Health Board in the United Kingdom, involving 56 patients who underwent robotic-assisted colorectal resections for CRC. Patients aged ≥18 years with radiologically and endoscopically confirmed non-metastatic CRC (American Joint Committee on Cancer stage T1-4, N0-2, M0) were included. Data on preoperative, intraoperative, and postoperative parameters were collected. Operative details included procedure type, console time, and estimated blood loss. Complications were graded using the Clavien-Dindo classification. Analyses were performed using SPSS version 26 (IBM Corp., Armonk, NY, USA). Categorical variables were reported as frequencies and percentages; continuous variables as means ± SD or medians with interquartile ranges. Chi-square, independent t-tests, or Mann-Whitney U tests were used for group comparisons. A p-value <0.05 was considered significant. Results The mean operative time was 131 ± 50.99 minutes. In-hospital complications occurred in 37.5% of patients, predominantly local (26.8%) over systemic (10.7%). No significant association was found between preoperative variables and postoperative complications. No perioperative mortality occurred. Conclusions The Versius® system demonstrates feasibility and safety for CRC resections, with acceptable complication rates and no mortality, supporting its use as a promising approach in robotic colorectal surgery.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-03
DOI
https://doi.org/10.7759/cureus.93786
Citations
1
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
1.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of Robotics in Colorectal Surgery: An Initial Single-Centre Experience

Steve Dixon, Anurag Agarwal, Sjaak Pouwels, Ahmed R. Ahmed et al.
1 citations
Cureus
Colorectal Cancer Surgical Treatments
1.05
article

Use of Robotics in Colorectal Surgery: An Initial Single-Centre Experience

Steve Dixon, Anurag Agarwal, Sjaak Pouwels, Ahmed R. Ahmed, Suhaib Ahmad, Graham Whiteley, Anil K. Lala, Sheik Rehman
article en
1 citations

Abstract

Background Robotic-assisted surgery is increasingly recognised as a viable alternative to conventional open and laparoscopic techniques in colorectal cancer (CRC) management. This study presents a single-centre initial experience with the Versius® robotic system for colorectal resections between April 2023 and March 2024. Methodology A retrospective cohort study was conducted at a University Health Board in the United Kingdom, involving 56 patients who underwent robotic-assisted colorectal resections for CRC. Patients aged ≥18 years with radiologically and endoscopically confirmed non-metastatic CRC (American Joint Committee on Cancer stage T1-4, N0-2, M0) were included. Data on preoperative, intraoperative, and postoperative parameters were collected. Operative details included procedure type, console time, and estimated blood loss. Complications were graded using the Clavien-Dindo classification. Analyses were performed using SPSS version 26 (IBM Corp., Armonk, NY, USA). Categorical variables were reported as frequencies and percentages; continuous variables as means ± SD or medians with interquartile ranges. Chi-square, independent t-tests, or Mann-Whitney U tests were used for group comparisons. A p-value <0.05 was considered significant. Results The mean operative time was 131 ± 50.99 minutes. In-hospital complications occurred in 37.5% of patients, predominantly local (26.8%) over systemic (10.7%). No significant association was found between preoperative variables and postoperative complications. No perioperative mortality occurred. Conclusions The Versius® system demonstrates feasibility and safety for CRC resections, with acceptable complication rates and no mortality, supporting its use as a promising approach in robotic colorectal surgery.

CureusVol. 17(10)
Glan Clwyd Hospital (GB), Betsi Cadwaladr University Health Board (GB), Bangor University (GB), Elisabeth-TweeSteden Ziekenhuis (NL), Imperial College London (GB)
Openalex Percentile: Top 17%
Colorectal Cancer Surgical Treatments
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.