Traceability of S-Parameter Measurements Up to 167 GHz Using 0.8 mm Coaxial Standards
To establish traceable S-parameter measurements in the 0.8 mm coaxial connector system, dimensional measurements are performed on a set of seven offset short standards. Reflection coefficients for each standard are calculated numerically and analytically based on these dimensions. S-parameter measurements are conducted for one-port devices up to 167 GHz, and an optimization-based calibration is applied, treating material properties as free parameters. Selected measurement results are presented, and associated uncertainty budgets are discussed.
Authors
- Florian Rausche
- Karsten Kuhlmann (ORCID: https://orcid.org/0000-0002-4022-7061)
- Frauke Gellersen (ORCID: https://orcid.org/0000-0001-9062-2927)
- Andreas Schramm (ORCID: https://orcid.org/0009-0006-4639-7535)
Institutions
- Physikalisch-Technische Bundesanstalt (DE)
Publication Details
- Journal
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2025-10-03
- DOI
- https://doi.org/10.1109/tmtt.2025.3613009
- Primary Topic
- Gyrotron and Vacuum Electronics Research
- Type
- article
- Field-Weighted Citation Impact
- 0.00