Ultra-sensitive wide-angle and polarization-independent terahertz metamaterial absorbers for early detection of basal cell carcinoma

Abstract Terahertz metamaterial absorbers have come to the forefront of biosensing applications due to the non-ionizing characteristics and sensitivity to weak interactions of the terahertz radiation. This article presents a novel design of graphene-based terahertz metasurface absorber (MSA) aimed at early label-free cancerous cell detection. The design consists of two concentric hexagonal graphene rings placed on top of a SiO 2 dielectric layer, followed by a gold metallic ground plane. We achieve a near-perfect absorption of 97% at 3.275 THz with a Q-factor of 22.061. The simulated spectral characteristics are verified analytically using the impedance matching theory. A near-perfect absorption at the resonant frequency can be attributed to the effective excitation of localized surface plasmon modes. The proposed biosensor demonstrates a sensitivity of 0.622 THz RIU −1 , and a figure of merit (FoM) of 4.49 RIU −1 in response to the normal cell. On the contrary, it shows a sensitivity of 0.626 THz RIU −1 , and a FoM of 4.42 RIU −1 in response to the basal carcinoma cells. A parametric study of the thickness and refractive index of the analyte suggests that the proposed design may be applied to the detection of thin films of biological samples. Furthermore, the effect of changes in the chemical potential and relaxation time of Graphene is also investigated. The MSA is polarization-independent and shows wide incident angle stability (up to 60°). The sensitivity and FoM calculations suggest that the proposed MSA can outperform recently reported biosensors, potentially leading to a significant improvement in diagnostic accuracy for early-stage cancer detection.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2025-10-01
DOI
https://doi.org/10.1088/1402-4896/ae0f64
Citations
1
Primary Topic
Terahertz technology and applications
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultra-sensitive wide-angle and polarization-independent terahertz metamaterial absorbers for early detection of basal cell carcinoma

Ashish Kumar Chowdhary, S. Vincent, Anuradha Kumari
1 citations
Physica Scripta
Terahertz technology and applications
0.73
article

Ultra-sensitive wide-angle and polarization-independent terahertz metamaterial absorbers for early detection of basal cell carcinoma

Ashish Kumar Chowdhary, S. Vincent, Anuradha Kumari
article en
1 citations

Abstract

Abstract Terahertz metamaterial absorbers have come to the forefront of biosensing applications due to the non-ionizing characteristics and sensitivity to weak interactions of the terahertz radiation. This article presents a novel design of graphene-based terahertz metasurface absorber (MSA) aimed at early label-free cancerous cell detection. The design consists of two concentric hexagonal graphene rings placed on top of a SiO 2 dielectric layer, followed by a gold metallic ground plane. We achieve a near-perfect absorption of 97% at 3.275 THz with a Q-factor of 22.061. The simulated spectral characteristics are verified analytically using the impedance matching theory. A near-perfect absorption at the resonant frequency can be attributed to the effective excitation of localized surface plasmon modes. The proposed biosensor demonstrates a sensitivity of 0.622 THz RIU −1 , and a figure of merit (FoM) of 4.49 RIU −1 in response to the normal cell. On the contrary, it shows a sensitivity of 0.626 THz RIU −1 , and a FoM of 4.42 RIU −1 in response to the basal carcinoma cells. A parametric study of the thickness and refractive index of the analyte suggests that the proposed design may be applied to the detection of thin films of biological samples. Furthermore, the effect of changes in the chemical potential and relaxation time of Graphene is also investigated. The MSA is polarization-independent and shows wide incident angle stability (up to 60°). The sensitivity and FoM calculations suggest that the proposed MSA can outperform recently reported biosensors, potentially leading to a significant improvement in diagnostic accuracy for early-stage cancer detection.

Physica ScriptaVol. 100(10)
National Institute of Technology Calicut (IN), Indian Institute of Technology Roorkee (IN), Indian Institute of Technology Delhi (IN)
Openalex Percentile: Top 23%
Terahertz technology and applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.