Enhanced PLS subspace-based calibration transfer method for multiple spectrometers using small standardization sample sets
Near-infrared spectroscopy (NIRS) calibration transfer faces significant challenges when deploying models across multiple instruments from different manufacturers, particularly because the inherently low molar absorptivity makes spectral data highly sensitive to minor variations in optical setup. This study presents two enhanced calibration transfer methods (ICTWM1 and ICTWM2) operating within the PLS latent variable space, utilizing dimensionality reduction to preserve analytically relevant variance while reducing noise interference. ICTWM1 employs spectral space transformation (SST) to correct PLS component scores between different instruments, while ICTWM2 selectively corrects the regression coefficients of the principal components with the highest variability. The methods were validated using wheat protein analysis (7 secondary instruments from manufacturers A and B) and industrial sugarcane Brix determination (8 secondary instruments across geographically distributed facilities). ICTWM1 demonstrated superior performance, achieving 79.3% relative performance compared to the primary instrument model using only 10 standardization samples on the wheat dataset, with improved cross-instrument consistency (standard deviations of 3.4%-6.9%) compared to traditional methods (>15%). The method exhibited no manufacturer-dependent performance bias and maintained consistent performance across sample sizes ranging from 10 to 110. Under severely constrained sugarcane dataset with only 5 training samples, both ICTWM1 and ICTWM2 achieved good performance with mean RMSEP values of 0.14°Bx and 0.15°Bx, respectively, outperforming traditional calibration transfer methods. ICTWM1 demonstrates improved sample efficiency and cross-manufacturer robustness through optimized transformation within PLS subspace. These characteristics make it a practical method for industrial NIRS applications requiring reliable calibration transfer with minimal standardization samples. • Enhanced PLS subspace methods for calibration transfer with minimal standardization samples • Comprehensive validation across 7-8 secondary instruments using public and industrial datasets • Superior accuracy and cross-instrument consistency under minimal sample conditions • Practical method for sample-efficient multivariate calibration transfer in NIRS
Authors
- Eizo Taira (ORCID: https://orcid.org/0000-0002-6766-128X)
- Tetsuya Inagaki (ORCID: https://orcid.org/0000-0002-5382-1940)
- Bin Li (ORCID: https://orcid.org/0009-0000-6147-3301)
Institutions
- University of the Ryukyus (JP)
- Nagoya University (JP)
Publication Details
- Journal
- Chemometrics and Intelligent Laboratory Systems
- Published
- 2025-10-03
- DOI
- https://doi.org/10.1016/j.chemolab.2025.105545
- Primary Topic
- Spectroscopy and Chemometric Analyses
- Type
- article
- Field-Weighted Citation Impact
- 0.00