Portable 3D-printed electrochemiluminescence sensor for simultaneous glucose and lactate monitoring

Fast and reliable monitoring of metabolic biomarkers, including glucose and lactate, is critical for chronic diseases, sepsis, and other scenarios involving physiological stress. However, most diagnostic options depend on multiple serial tests, require complicated testing apparatus, and are too expensive to be useful in the point-of-care arena. To address these limitations, we present a portable, low-cost, and 3D-printed (3DP) electrochemiluminescence (ECL) biosensor capable of simultaneously detecting glucose and lactate in a single step. The biosensor incorporates interdigitated electrodes (IDEs) within a bipolar electrode (BPE) electrochemical system to enhance electron transfer and signal amplification. Through careful optimization of voltage, luminol concentration, and pH, strong and reproducible ECL signals were achieved, with detection limits of 0.1 mM for glucose (linear range 0.1 mM to 5.0 mM) and 80 µM for lactate (linear range 0.1 mM to 4.0 mM). Real serum analysis yielded 95-102% recovery rates, validating the device's clinical relevance. Combining an inexpensive smartphone-based readout and fabricated with low-cost carbon and polylactic acid (PLA) filaments, this device offers a scalable and field-deployable approach to real-time, decentralized diagnostics. The proposed prototype fills a critical void between laboratory analysis and standard healthcare needs and promotes accessible and affordable metabolic monitoring for underserved populations.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-03
DOI
https://doi.org/10.1038/s41598-025-18109-4
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable 3D-printed electrochemiluminescence sensor for simultaneous glucose and lactate monitoring

Sarika Khandelwal, Madhusudan B. Kulkarni, Purshottam J. Assudani, Manish L. Bhaiyya et al.
5 citations
Scientific Reports
Advanced biosensing and bioanalysis techniques
4.03
article

Portable 3D-printed electrochemiluminescence sensor for simultaneous glucose and lactate monitoring

Sarika Khandelwal, Madhusudan B. Kulkarni, Purshottam J. Assudani, Manish L. Bhaiyya, Amol S. Kulkarni, Kavita Manekar, Rangnath Girhe
article en
5 citations

Abstract

Fast and reliable monitoring of metabolic biomarkers, including glucose and lactate, is critical for chronic diseases, sepsis, and other scenarios involving physiological stress. However, most diagnostic options depend on multiple serial tests, require complicated testing apparatus, and are too expensive to be useful in the point-of-care arena. To address these limitations, we present a portable, low-cost, and 3D-printed (3DP) electrochemiluminescence (ECL) biosensor capable of simultaneously detecting glucose and lactate in a single step. The biosensor incorporates interdigitated electrodes (IDEs) within a bipolar electrode (BPE) electrochemical system to enhance electron transfer and signal amplification. Through careful optimization of voltage, luminol concentration, and pH, strong and reproducible ECL signals were achieved, with detection limits of 0.1 mM for glucose (linear range 0.1 mM to 5.0 mM) and 80 µM for lactate (linear range 0.1 mM to 4.0 mM). Real serum analysis yielded 95-102% recovery rates, validating the device's clinical relevance. Combining an inexpensive smartphone-based readout and fabricated with low-cost carbon and polylactic acid (PLA) filaments, this device offers a scalable and field-deployable approach to real-time, decentralized diagnostics. The proposed prototype fills a critical void between laboratory analysis and standard healthcare needs and promotes accessible and affordable metabolic monitoring for underserved populations.

Scientific ReportsVol. 15(1)
Government of Maharashtra (IN), Sant Gadge Baba Amravati University (IN), Manipal Academy of Higher Education (IN), Technion – Israel Institute of Technology (IL), Rama University (IN), Government Medical College (IN), Raisoni Group of Institutions (IN)
Openalex Percentile: Top 6%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.