O040 Inter-night variability of nocturnal pulse-oximetry in people living with MND

Abstract Background and objective Nocturnal pulse oximetry (NPO) is a simple and inexpensive assessment tool that has previously been shown to correlate with prognosis and timing of non-invasive ventilation (NIV) initiation in people living with motor neuron disease (plwMND). However, the optimal number of nights for measuring NPO has not been defined for this population, with other respiratory conditions exhibiting both low and high night-to-night variability in NPO parameters. This study aims to determine the inter-night variability in NPO data over three nights in plwMND. Methods We conducted a retrospective analysis of 132 studies in which plwMND underwent three consecutive nights of NPO. Intraclass correlation coefficients (ICC) were used to assess the reliability of key NPO parameters, including mean percentage of total recording time with oxygen saturation (SpO₂) <90% (T90), oxygen desaturation index (ODI), basal SpO₂, and nadir SpO₂. The proportion of plwMND meeting NIV criteria based on single-night versus multi-night assessments was also compared. Results Excellent reliability was observed for T90 (ICC(1) = 0.940) and ODI (ICC(1) = 0.901), while basal SpO₂ (ICC(1) = 0.845) and nadir SpO₂ (ICC(1) = 0.768) demonstrated good reliability. However, relying on a single-night NPO assessment failed to identify 12% of plwMND who met NIV criteria when evaluated over three nights. Conclusion Despite good to excellent inter-night variability of NPO data in plwMND, multi-night NPO monitoring improves the accuracy of identifying plwMND requiring NIV. These findings support the need for multi-night assessments to enhance clinical decision-making in MND management.

Authors

Institutions

Publication Details

Journal
SLEEP Advances
Published
2025-10-01
DOI
https://doi.org/10.1093/sleepadvances/zpaf053.040
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O040 Inter-night variability of nocturnal pulse-oximetry in people living with MND

Brendon J. Yee, Amanda J. Piper, Keith Wong, O McGuiness et al.
SLEEP Advances
Non-Invasive Vital Sign Monitoring
article

O040 Inter-night variability of nocturnal pulse-oximetry in people living with MND

Brendon J. Yee, Amanda J. Piper, Keith Wong, O McGuiness, Emma L. Gray, Collette Menadue, Steven Luu
article en

Abstract

Abstract Background and objective Nocturnal pulse oximetry (NPO) is a simple and inexpensive assessment tool that has previously been shown to correlate with prognosis and timing of non-invasive ventilation (NIV) initiation in people living with motor neuron disease (plwMND). However, the optimal number of nights for measuring NPO has not been defined for this population, with other respiratory conditions exhibiting both low and high night-to-night variability in NPO parameters. This study aims to determine the inter-night variability in NPO data over three nights in plwMND. Methods We conducted a retrospective analysis of 132 studies in which plwMND underwent three consecutive nights of NPO. Intraclass correlation coefficients (ICC) were used to assess the reliability of key NPO parameters, including mean percentage of total recording time with oxygen saturation (SpO₂) <90% (T90), oxygen desaturation index (ODI), basal SpO₂, and nadir SpO₂. The proportion of plwMND meeting NIV criteria based on single-night versus multi-night assessments was also compared. Results Excellent reliability was observed for T90 (ICC(1) = 0.940) and ODI (ICC(1) = 0.901), while basal SpO₂ (ICC(1) = 0.845) and nadir SpO₂ (ICC(1) = 0.768) demonstrated good reliability. However, relying on a single-night NPO assessment failed to identify 12% of plwMND who met NIV criteria when evaluated over three nights. Conclusion Despite good to excellent inter-night variability of NPO data in plwMND, multi-night NPO monitoring improves the accuracy of identifying plwMND requiring NIV. These findings support the need for multi-night assessments to enhance clinical decision-making in MND management.

SLEEP AdvancesVol. 6(Supplement_1)
The University of Sydney (AU), Royal Prince Alfred Hospital (AU), Woolcock Institute of Medical Research (AU)
Openalex Percentile: Top 74%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.