O055 CPAP adherence in practice: do endotypes hold predictive value?

Abstract Introduction Obstructive Sleep Apnoea (OSA) is commonly treated with Continuous Positive Airway Pressure (CPAP), but adherence to therapy is often poor in real-world settings. Recent physiology lab studies have identified physiological OSA endotypes that may influence patient tolerance to CPAP treatment and, in turn, adherence outcomes. This pilot study investigates whether this physiological bias against CPAP is detectable in real-world populations by examining correlations between endotype metrics and long-term CPAP adherence in a clinical cohort. Methods Data from 40 adult OSA patients with diagnostic polysomnography and long-term CPAP adherence records was extracted from our institutional research database and retrospectively analysed. Two matched sub-cohorts with good and poor CPAP adherence were defined. Polysomnographic signals were processed using existing methods to estimate the values of four physiological OSA endotypes: chemoreflex loop gain, critical airway pressure (Pcrit), respiratory arousal threshold, and pharyngeal muscle responsiveness. Endotype distributions were statistically compared between the two groups. Results None of the four endotypes showed statistically significant differences between the adherent and non-adherent groups. Weak correlations were observed between adherence and both Pcrit and arousal threshold, aligning with existing physiological models of CPAP response. Discussion This study did not find significant associations between physiological endotypes and CPAP adherence in a clinical cohort. While weak trends consistent with previous mechanistic hypotheses were observed, these findings suggest that endotypes alone may have limited predictive value in real-world settings. Ongoing work is evaluating these associations in a large-scale cohort to account for potential confounding factors such as behavioural and socio-environmental influences.

Authors

Institutions

Publication Details

Journal
SLEEP Advances
Published
2025-10-01
DOI
https://doi.org/10.1093/sleepadvances/zpaf053.055
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

O055 CPAP adherence in practice: do endotypes hold predictive value?

Nicola Malagutti, Stephanie Miller, Li Chen
SLEEP Advances
Obstructive Sleep Apnea Research
article

O055 CPAP adherence in practice: do endotypes hold predictive value?

Nicola Malagutti, Stephanie Miller, Li Chen
article en

Abstract

Abstract Introduction Obstructive Sleep Apnoea (OSA) is commonly treated with Continuous Positive Airway Pressure (CPAP), but adherence to therapy is often poor in real-world settings. Recent physiology lab studies have identified physiological OSA endotypes that may influence patient tolerance to CPAP treatment and, in turn, adherence outcomes. This pilot study investigates whether this physiological bias against CPAP is detectable in real-world populations by examining correlations between endotype metrics and long-term CPAP adherence in a clinical cohort. Methods Data from 40 adult OSA patients with diagnostic polysomnography and long-term CPAP adherence records was extracted from our institutional research database and retrospectively analysed. Two matched sub-cohorts with good and poor CPAP adherence were defined. Polysomnographic signals were processed using existing methods to estimate the values of four physiological OSA endotypes: chemoreflex loop gain, critical airway pressure (Pcrit), respiratory arousal threshold, and pharyngeal muscle responsiveness. Endotype distributions were statistically compared between the two groups. Results None of the four endotypes showed statistically significant differences between the adherent and non-adherent groups. Weak correlations were observed between adherence and both Pcrit and arousal threshold, aligning with existing physiological models of CPAP response. Discussion This study did not find significant associations between physiological endotypes and CPAP adherence in a clinical cohort. While weak trends consistent with previous mechanistic hypotheses were observed, these findings suggest that endotypes alone may have limited predictive value in real-world settings. Ongoing work is evaluating these associations in a large-scale cohort to account for potential confounding factors such as behavioural and socio-environmental influences.

SLEEP AdvancesVol. 6(Supplement_1)
Australian National University (AU), Canberra Hospital (AU), National Computational Infrastructure (AU)
Openalex Percentile: Top 65%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.