Novel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils

The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors—such as defect formation—can hinder accurate event-energy interpretation. Neutron capture <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline"><a:mo stretchy="false">(</a:mo><a:mi>n</a:mi><a:mo>,</a:mo><a:mi>γ</a:mi><a:mo stretchy="false">)</a:mo></a:math> can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture—the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure.

Authors

Institutions

Publication Details

Journal
Physical review. D/Physical review. D.
Published
2025-10-03
DOI
https://doi.org/10.1103/7bnf-mxjz
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils

A. J. Biffl, N. Mirabolfathi, A. N. Villano, Gerardo González
Physical review. D/Physical review. D.
Radiation Detection and Scintillator Technologies
article

Novel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils

A. J. Biffl, N. Mirabolfathi, A. N. Villano, Gerardo González
article en

Abstract

The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors—such as defect formation—can hinder accurate event-energy interpretation. Neutron capture <a:math xmlns:a="http://www.w3.org/1998/Math/MathML" display="inline"><a:mo stretchy="false">(</a:mo><a:mi>n</a:mi><a:mo>,</a:mo><a:mi>γ</a:mi><a:mo stretchy="false">)</a:mo></a:math> can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture—the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure.

Physical review. D/Physical review. D.Vol. 112(7)
Mitchell Institute (US), Texas A&M University (US), University of Colorado Denver (US)
Openalex Percentile: Top 63%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.