Comparative Study of DDA and DIA Acquisition Modes on UPLC-Q-Orbitrap Mass Spectrometry Using Huaihua Powder

This study systematically evaluates the comparative performance of two mass spectrometry acquisition modes, data-dependent acquisition (DDA) and data-independent acquisition (DIA), coupled with ultra-high-performance liquid chromatography-quadrupole-orbitrap high-resolution mass spectrometry (UPLC-Q-Orbitrap HRMS) for comprehensive chemical profiling of complex traditional Chinese medicine (TCM) formulations. Huaihua Powder, a classical formulated prescription, was employed as a model system for empirical assessment. Optimized DDA and DIA acquisition methods were separately established: the DDA method incorporated a targeted precursor ion selection strategy with customized fragmentation parameters, while the DIA method employed a segmented variable window strategy to cover the target m/z range, performing unbiased fragmentation on all precursor ions. Compound identification was executed using Compound Discoverer software. The comparative evaluation specifically focused on the performance characteristics of the two acquisition modes, encompassing the number of identified compounds, reproducibility, MS/MS spectral quality, and detection sensitivity for low-abundance active constituents. Results demonstrated that the DDA mode yielded a higher total number of detected compounds, whereas the DIA mode generated a greater proportion of high-confidence identifications (10.63 % with spectral match scores >0.8). Notably, the DIA approach exhibited significantly superior reproducibility in retention time and peak area for six representative compounds, with rutin showing >3-fold difference in retention time RSD between the two acquisition modes. However, DDA produced cleaner MS/MS spectra with distinct fragment ions, whereas DIA spectra exhibited interference from contaminant ions. Concurrently, DIA effectively detected low-abundance active constituents whose ion chromatograms and MS/MS fragments could not be extracted in DDA mode. This study contributes critical experimental evidence and analytical datasets to inform the selection of high-resolution mass spectrometry acquisition modes for complex TCM formulation research. Subsequent researchers may integrate the complementary advantages of both approaches to achieve dual objectives in comprehensive compound characterization.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2025-10-03
DOI
https://doi.org/10.3791/69227
Primary Topic
Traditional Chinese Medicine Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of DDA and DIA Acquisition Modes on UPLC-Q-Orbitrap Mass Spectrometry Using Huaihua Powder

Maoyuan Jiang, L. Q. Wang, Yin Lei, Ruijun Zhang et al.
Journal of Visualized Experiments
Traditional Chinese Medicine Analysis
article

Comparative Study of DDA and DIA Acquisition Modes on UPLC-Q-Orbitrap Mass Spectrometry Using Huaihua Powder

Maoyuan Jiang, L. Q. Wang, Yin Lei, Ruijun Zhang, Jing Nie, Di Wang
article en

Abstract

This study systematically evaluates the comparative performance of two mass spectrometry acquisition modes, data-dependent acquisition (DDA) and data-independent acquisition (DIA), coupled with ultra-high-performance liquid chromatography-quadrupole-orbitrap high-resolution mass spectrometry (UPLC-Q-Orbitrap HRMS) for comprehensive chemical profiling of complex traditional Chinese medicine (TCM) formulations. Huaihua Powder, a classical formulated prescription, was employed as a model system for empirical assessment. Optimized DDA and DIA acquisition methods were separately established: the DDA method incorporated a targeted precursor ion selection strategy with customized fragmentation parameters, while the DIA method employed a segmented variable window strategy to cover the target m/z range, performing unbiased fragmentation on all precursor ions. Compound identification was executed using Compound Discoverer software. The comparative evaluation specifically focused on the performance characteristics of the two acquisition modes, encompassing the number of identified compounds, reproducibility, MS/MS spectral quality, and detection sensitivity for low-abundance active constituents. Results demonstrated that the DDA mode yielded a higher total number of detected compounds, whereas the DIA mode generated a greater proportion of high-confidence identifications (10.63 % with spectral match scores >0.8). Notably, the DIA approach exhibited significantly superior reproducibility in retention time and peak area for six representative compounds, with rutin showing >3-fold difference in retention time RSD between the two acquisition modes. However, DDA produced cleaner MS/MS spectra with distinct fragment ions, whereas DIA spectra exhibited interference from contaminant ions. Concurrently, DIA effectively detected low-abundance active constituents whose ion chromatograms and MS/MS fragments could not be extracted in DDA mode. This study contributes critical experimental evidence and analytical datasets to inform the selection of high-resolution mass spectrometry acquisition modes for complex TCM formulation research. Subsequent researchers may integrate the complementary advantages of both approaches to achieve dual objectives in comprehensive compound characterization.

Journal of Visualized Experiments(224)
Chengdu University of Traditional Chinese Medicine (CN)
Openalex Percentile: Top 57%
Traditional Chinese Medicine Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.