New calibration method for skin calorimeters without baseline correction for continuous heat flux measurement

Abstract In this study, we present a new calibration method for a skin calorimeter that allows continuous measurement on the skin without the need for baseline correction. This approach is essential for practical applications that require immediate and uninterrupted monitoring, such as in clinical and physiological studies. The skin calorimeter, designed to measure heat flux, heat capacity, and thermal resistance of a 2 × 2 cm 2 skin area, is calibrated using a small aluminum block with a built-in resistor and temperature sensor. Calibration was performed over a range of thermostat temperatures (26–32 ºC) and Peltier currents (25, 75, and 125 mA), resulting in an accurate model, with a root mean square error (RMSE) of less than 0.15 mW in power measurements. The calorimeter's performance was validated through experiments on human subjects, demonstrating accurate and reliable heat flux measurements without baseline correction. This method simplifies the measurement process and enhances the practical utility of skin calorimetry in various applications.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Analysis and Calorimetry
Published
2025-10-01
DOI
https://doi.org/10.1007/s10973-025-14709-4
Primary Topic
thermodynamics and calorimetric analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New calibration method for skin calorimeters without baseline correction for continuous heat flux measurement

Pedro Jesús Rodríguez de Rivera, Manuel Rodríguez de Rivera, Fabiola Socorro, Miriam Rodríguez de Rivera
Journal of Thermal Analysis and Calorimetry
thermodynamics and calorimetric analyses
article

New calibration method for skin calorimeters without baseline correction for continuous heat flux measurement

Pedro Jesús Rodríguez de Rivera, Manuel Rodríguez de Rivera, Fabiola Socorro, Miriam Rodríguez de Rivera
article en

Abstract

Abstract In this study, we present a new calibration method for a skin calorimeter that allows continuous measurement on the skin without the need for baseline correction. This approach is essential for practical applications that require immediate and uninterrupted monitoring, such as in clinical and physiological studies. The skin calorimeter, designed to measure heat flux, heat capacity, and thermal resistance of a 2 × 2 cm 2 skin area, is calibrated using a small aluminum block with a built-in resistor and temperature sensor. Calibration was performed over a range of thermostat temperatures (26–32 ºC) and Peltier currents (25, 75, and 125 mA), resulting in an accurate model, with a root mean square error (RMSE) of less than 0.15 mW in power measurements. The calorimeter's performance was validated through experiments on human subjects, demonstrating accurate and reliable heat flux measurements without baseline correction. This method simplifies the measurement process and enhances the practical utility of skin calorimetry in various applications.

Journal of Thermal Analysis and CalorimetryVol. 150(19)
Universidad de Las Palmas de Gran Canaria (ES), Marqués de Valdecilla University Hospital (ES)
Openalex Percentile: Top 74%
thermodynamics and calorimetric analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.