Electrode-Proximal 3D Particle Focusing via Acoustic Streaming for High-Sensitivity Sheathless Impedance Flow Cytometry

The nonuniform electric field generated by coplanar electrodes in microfluidic impedance flow cytometry (MIFC) introduces a position-dependent factor, which is a critical challenge for the sensitivity and accuracy of measured signals. To address this challenge, we put forward a novel MIFC configuration by monolithic on-chip integration of a bulk acoustic wave resonator with a pair of coplanar electrodes. This design utilizes the acoustic streaming effect to achieve three-dimensional (3D) particle focusing, enabling the particles to traverse the downstream impedance sensing region along a consistent trajectory in the electrode near-field region. This not only mitigates the position-dependent variability but also leverages the inherent electric field distribution characteristics of coplanar electrodes to enhance detection sensitivity. The experimental results demonstrated efficient focusing performance across various sample flow rates, with a coefficient of variation (C.V.) of 1.7% for 5 μm diameter particles. Furthermore, the substantial improvement in impedance measurement precision and sensitivity not only enhances the accuracy of size-based detection and discrimination at low frequencies but also supports more reliable multifrequency impedance analysis, thereby providing a more precise insight into the electrophysiology of the cell interior. In conclusion, this work presents a promising methodology for overcoming the position-dependent factor and enhancing detection sensitivity without the necessity for an additional sheath flow system or complex signal processing.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-10-03
DOI
https://doi.org/10.1021/acssensors.5c02714
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrode-Proximal 3D Particle Focusing via Acoustic Streaming for High-Sensitivity Sheathless Impedance Flow Cytometry

Yongqi Chen, Xuexin Duan, Wei Wei, Haoran Zhang et al.
ACS Sensors
Microfluidic and Bio-sensing Technologies
article

Electrode-Proximal 3D Particle Focusing via Acoustic Streaming for High-Sensitivity Sheathless Impedance Flow Cytometry

Yongqi Chen, Xuexin Duan, Wei Wei, Haoran Zhang, Xuejiao Chen, Ziyu Han, Yaping Wang
article en

Abstract

The nonuniform electric field generated by coplanar electrodes in microfluidic impedance flow cytometry (MIFC) introduces a position-dependent factor, which is a critical challenge for the sensitivity and accuracy of measured signals. To address this challenge, we put forward a novel MIFC configuration by monolithic on-chip integration of a bulk acoustic wave resonator with a pair of coplanar electrodes. This design utilizes the acoustic streaming effect to achieve three-dimensional (3D) particle focusing, enabling the particles to traverse the downstream impedance sensing region along a consistent trajectory in the electrode near-field region. This not only mitigates the position-dependent variability but also leverages the inherent electric field distribution characteristics of coplanar electrodes to enhance detection sensitivity. The experimental results demonstrated efficient focusing performance across various sample flow rates, with a coefficient of variation (C.V.) of 1.7% for 5 μm diameter particles. Furthermore, the substantial improvement in impedance measurement precision and sensitivity not only enhances the accuracy of size-based detection and discrimination at low frequencies but also supports more reliable multifrequency impedance analysis, thereby providing a more precise insight into the electrophysiology of the cell interior. In conclusion, this work presents a promising methodology for overcoming the position-dependent factor and enhancing detection sensitivity without the necessity for an additional sheath flow system or complex signal processing.

ACS SensorsVol. 10(10)
Tianjin University (CN), Research Institute of Precision Instruments (Russia) (RU)
Openalex Percentile: Top 74%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.