Integration of the CAEN Front-End Readout System for Calorimeters within the miniSPD Setup

The integration and application of the CAEN front-end readout system within the miniSPD facility is presented, with a focus on calorimeter modules. The miniSPD is designed for cosmic muon testing of the detectors planned for use in the SPD facility, including straw, silicon, and Micromegas trackers, along with electromagnetic calorimeters. The main objectives include verifying the functionality and performance of modern electronics, testing the CAEN system’s suitability for miniSPD, and obtaining real cosmic ray data. By using prototype detectors and measuring key detector parameters such as spatial and temporal resolution, efficiency, and stability, this work aims to assess the system’s long-term operation reliability. The system was tested to produce key spectra, including the staircase spectrum, Landau distribution, and cosmic ray data, with additional upcoming results focused on SPD calorimeters. The results of using these electronics for straw-tracker prototypes are also presented, where the spectra of Fe-55 and Ru-106 are shown.

Authors

Institutions

Publication Details

Journal
Physics of Particles and Nuclei Letters
Published
2025-10-01
DOI
https://doi.org/10.1134/s154747712570133x
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of the CAEN Front-End Readout System for Calorimeters within the miniSPD Setup

O. Gavrishchuk, T. Enik, S. Romakhov, N. Saktaganov
Physics of Particles and Nuclei Letters
Calibration and Measurement Techniques
article

Integration of the CAEN Front-End Readout System for Calorimeters within the miniSPD Setup

O. Gavrishchuk, T. Enik, S. Romakhov, N. Saktaganov
article en

Abstract

The integration and application of the CAEN front-end readout system within the miniSPD facility is presented, with a focus on calorimeter modules. The miniSPD is designed for cosmic muon testing of the detectors planned for use in the SPD facility, including straw, silicon, and Micromegas trackers, along with electromagnetic calorimeters. The main objectives include verifying the functionality and performance of modern electronics, testing the CAEN system’s suitability for miniSPD, and obtaining real cosmic ray data. By using prototype detectors and measuring key detector parameters such as spatial and temporal resolution, efficiency, and stability, this work aims to assess the system’s long-term operation reliability. The system was tested to produce key spectra, including the staircase spectrum, Landau distribution, and cosmic ray data, with additional upcoming results focused on SPD calorimeters. The results of using these electronics for straw-tracker prototypes are also presented, where the spectra of Fe-55 and Ru-106 are shown.

Physics of Particles and Nuclei LettersVol. 22(5)
Joint Institute for Nuclear Research (RU)
Openalex Percentile: Top 64%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Integration of the CAEN Front-End Readout System for Calorimeters within the miniSPD Setup — O. Gavrishchuk, T. Enik, et al. · Physics of Particles and Nuclei Letters (2025) | TGRS Research Map | TGRS