On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors

Electrochemical aptamer-based (EAB) sensors are the only high-frequency, real-time molecular measurement approach reported to date that is simultaneously both (1) selective enough to deploy in situ in the body and (2) independent of the chemical reactivity of its target, rendering it generalizable to the measurement of a wide range of analytes. To date, for example, a half dozen research groups have demonstrated the ability of EAB sensors to support few-second to subsecond resolved, multihour measurements of drugs and biomarkers in the veins, brains, and solid peripheral tissues of live rats. Motivated by the scientific and clinical applications these real-time, highly time-resolved in vivo measurements enable, significant literature has explored methods for improving the design, fabrication, and operation of EAB sensors. Here, we critically review this literature in an effort to identify what we believe are the most promising of these approaches and which are the areas of EAB sensor design, fabrication, and operation that remain to be profitably explored.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-10-03
DOI
https://doi.org/10.1021/acssensors.4c03465
Citations
12
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
8.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors

Yuyang Wu, Kevin W. Plaxco
12 citations
ACS Sensors
Analytical Chemistry and Sensors
8.84
article

On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors

Yuyang Wu, Kevin W. Plaxco
article en
12 citations

Abstract

Electrochemical aptamer-based (EAB) sensors are the only high-frequency, real-time molecular measurement approach reported to date that is simultaneously both (1) selective enough to deploy in situ in the body and (2) independent of the chemical reactivity of its target, rendering it generalizable to the measurement of a wide range of analytes. To date, for example, a half dozen research groups have demonstrated the ability of EAB sensors to support few-second to subsecond resolved, multihour measurements of drugs and biomarkers in the veins, brains, and solid peripheral tissues of live rats. Motivated by the scientific and clinical applications these real-time, highly time-resolved in vivo measurements enable, significant literature has explored methods for improving the design, fabrication, and operation of EAB sensors. Here, we critically review this literature in an effort to identify what we believe are the most promising of these approaches and which are the areas of EAB sensor design, fabrication, and operation that remain to be profitably explored.

ACS SensorsVol. 10(10)
University of California, Santa Barbara (US), Bioengineering Center (RU)
Openalex Percentile: Top 1%
Analytical Chemistry and Sensors
8.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On the Design, Fabrication, and Operation of Electrochemical Aptamer-Based Sensors — Yuyang Wu, Kevin W. Plaxco · ACS Sensors (2025) | TGRS Research Map | TGRS