Evaluation and Comparison of Single-Color and Multi-Parameter Photometric Temperature Calibrations with Gaia DR3 and Hipparcos Catalogue

we present a comparative analysis of two photometric calibration methods which is used to calculate the effective temperature and the uncertainties of 109 stars present in both Hipparcos and Gaia Dr3 catalogue .Stellar effective temperature were computed with (i) the color-temperature relation of Flower(1996)[5],which only uses B-V,and (ii)Casagrande(2010)[6] calibration that incorporates [Fe/H]. Values of B-V were taken from Hipparcos[3] and its input uncertainties were prop- agated through independent Monte Carlo [4] sampling(For input uncertainties of [Fe/H] their DR3 percentiles were converted to equivalent 1 sigma error which were propagated).(Gaia Dr3[2] effective temperature and uncertainties taken as refer- ence) by examining systematic offsets,scatter,the behaviour of normalised residuals and by testing how differences depends on metalicity.We must note that B-V used here are undereddened nor systematic correction was used to rectify either of the calibrations and Gaia itself has systematic uncertainties.

Authors

Publication Details

Published
2025-10-03
DOI
https://doi.org/10.38124/ijisrt/25sep1452
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation and Comparison of Single-Color and Multi-Parameter Photometric Temperature Calibrations with Gaia DR3 and Hipparcos Catalogue

Sayak Biswas
Calibration and Measurement Techniques
article

Evaluation and Comparison of Single-Color and Multi-Parameter Photometric Temperature Calibrations with Gaia DR3 and Hipparcos Catalogue

Sayak Biswas
article en

Abstract

we present a comparative analysis of two photometric calibration methods which is used to calculate the effective temperature and the uncertainties of 109 stars present in both Hipparcos and Gaia Dr3 catalogue .Stellar effective temperature were computed with (i) the color-temperature relation of Flower(1996)[5],which only uses B-V,and (ii)Casagrande(2010)[6] calibration that incorporates [Fe/H]. Values of B-V were taken from Hipparcos[3] and its input uncertainties were prop- agated through independent Monte Carlo [4] sampling(For input uncertainties of [Fe/H] their DR3 percentiles were converted to equivalent 1 sigma error which were propagated).(Gaia Dr3[2] effective temperature and uncertainties taken as refer- ence) by examining systematic offsets,scatter,the behaviour of normalised residuals and by testing how differences depends on metalicity.We must note that B-V used here are undereddened nor systematic correction was used to rectify either of the calibrations and Gaia itself has systematic uncertainties.

Openalex Percentile: Top 64%
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.