P055 Impact of humidification on bacterial filters and delivered pressures of PAP devices

Abstract Background In typical sleep laboratories, PAP devices are used on multiple patients in short periods of time. Some manufacturers recommend the use of bacterial filters to prevent cross contamination. Bacterial filters are known to increase resistance and reduce delivered pressures, especially at higher flow rates. While bacterial filters are manufactured to specific impedance values, humidification has the potential to increase their impedance in unpredictable ways. We aim to assess the impact of humidification on bacterial filters and delivered CPAP and determine whether pre- and post-study pressure measurements are required in lab-based PAP titration studies. Methods Delivered pressure was measured with a digital manometer at the beginning and end of 20 lab-based CPAP titration studies at four set-pressure points: 5, 10, 15 and 20cmH2O. To avoid tube rainout, humidification was set to 2 out of 5. To assess the impact of maximal humidification, additional measurements were taken before and after 8-hours of bench-testing at 20 cmH2O with humidification set to a 5 out 5. Progress to Date Six of eight studies (75%) have revealed no change (≤0.1cmH2O) in the delivered pressure after a full night of humidification. One study showed a small decrease of 0.3 cmH2O at 20 cmH2O, and one showed a marked decrease of 2.6 cmH2O. Currently, it is unclear what contributed to this marked decrease. Intended outcome and impact This study suggests that pre- and post-study pressure measurements should be taken during routine PAP titration studies when humidification is used in conjunction with bacterial filters.

Authors

Institutions

Publication Details

Journal
SLEEP Advances
Published
2025-10-01
DOI
https://doi.org/10.1093/sleepadvances/zpaf053.115
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

P055 Impact of humidification on bacterial filters and delivered pressures of PAP devices

J Stonehouse, Kirk Kee, Alan C. Perkins, A Cushnahan et al.
SLEEP Advances
Inhalation and Respiratory Drug Delivery
article

P055 Impact of humidification on bacterial filters and delivered pressures of PAP devices

J Stonehouse, Kirk Kee, Alan C. Perkins, A Cushnahan, S Dayal
article en

Abstract

Abstract Background In typical sleep laboratories, PAP devices are used on multiple patients in short periods of time. Some manufacturers recommend the use of bacterial filters to prevent cross contamination. Bacterial filters are known to increase resistance and reduce delivered pressures, especially at higher flow rates. While bacterial filters are manufactured to specific impedance values, humidification has the potential to increase their impedance in unpredictable ways. We aim to assess the impact of humidification on bacterial filters and delivered CPAP and determine whether pre- and post-study pressure measurements are required in lab-based PAP titration studies. Methods Delivered pressure was measured with a digital manometer at the beginning and end of 20 lab-based CPAP titration studies at four set-pressure points: 5, 10, 15 and 20cmH2O. To avoid tube rainout, humidification was set to 2 out of 5. To assess the impact of maximal humidification, additional measurements were taken before and after 8-hours of bench-testing at 20 cmH2O with humidification set to a 5 out 5. Progress to Date Six of eight studies (75%) have revealed no change (≤0.1cmH2O) in the delivered pressure after a full night of humidification. One study showed a small decrease of 0.3 cmH2O at 20 cmH2O, and one showed a marked decrease of 2.6 cmH2O. Currently, it is unclear what contributed to this marked decrease. Intended outcome and impact This study suggests that pre- and post-study pressure measurements should be taken during routine PAP titration studies when humidification is used in conjunction with bacterial filters.

SLEEP AdvancesVol. 6(Supplement_1)
The Royal Melbourne Hospital (AU), Monash University (AU)
Openalex Percentile: Top 60%
Inhalation and Respiratory Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

P055 Impact of humidification on bacterial filters and delivered pressures of PAP devices — J Stonehouse, Kirk Kee, et al. · SLEEP Advances (2025) | TGRS Research Map | TGRS